Optical Radiation Measurements Based on Detector Standards

نویسنده

  • George P. Eppeldauer
چکیده

A near-IR radiometer standard with similar performance to silicon trap-detectors has been developed to calibrate detectors and radiometers for absolute spectral power, irradiance, and radiance responsivities between 950 nm and 1650 nm. The new radiometer standard is utilized at the Spectral Irradiance and Radiance Responsivity Calibrations using Uniform Sources (SIRCUS) which is the reference calibration facility of NIST for absolute responsivity. The radiometer is a sphere-detector with a unique geometrical arrangement and it can convert the radiant-power responsivity scale of the primarystandard cryogenic-radiometer into a reference irradiance responsivity scale. The 0.05 % (k=2) scale conversion uncertainty is dominated by the two largest uncertainty components of the radiometer: The spatial non-uniformity of responsivity of less than 0.05 % in power mode and the 0.03 % angular responsivity deviation from the cosine function in a five-degree angular range in irradiance mode. These small uncertainty components are the results of a tilted input aperture (relative to the sphere-axis) and four symmetrically positioned InGaAs detectors around the incident beam-spot in the sphere. With the new radiometer standard, it is expected that a thermodynamic temperature uncertainty of 10 mK (k=2) can be achieved at 157 C the freeze temperature of the In fixed point blackbody.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ultraviolet radiometry with synchrotron radiation and cryogenic radiometry.

The combination of a cryogenic radiometer and synchrotron radiation enables detector scale realization in spectral regions that are otherwise difficult to access. Cryogenic radiometry is the most accurate primary detector-based standard available to date, and synchrotron radiation gives a unique broadband and continuous spectrum that extends from x ray to far IR. We describe a new cryogenic rad...

متن کامل

The Candela and Photometric and Radiometric Measurements

The national measurement system for photometric and radiometric quantities is presently based upon techniques that make these quantities traceable to a high-accuracy cryogenic radiometer. The redefinition of the candela in 1979 provided the opportunity for national measurement laboratories to base their photometric measurements on optical detector technology rather than on the emission from hig...

متن کامل

Assessment of basic physical and dosimetric parameters of synthetic single-crystal diamond detector and its use in Leksell Gamma Knife and CyberKnife small radiosurgical fields

Background: To determine the basic physical and dosimetric properties of a new synthetic single-crystal diamond detector and its application for relative small field dosimetry. Materials and Methods: The pre-irradiation dose required to stabilize detector response, dose rate dependence, photon and electron energy dependence, temperature dependence and angular dependence of MicroDiamond detector...

متن کامل

Bilateral Optical Power Meter Comparison Between NIST and CENAM*

We describe the results of a comparison of reference standards between the National Institute of Standards and Technology (NIST-USA) and Centro Nacional De Metrología (CENAM-Mexico). Open beam (free field) and optical-fiber-based measurements at wavelengths of 1302 nm and 1546 nm are reported. Both laboratories' reference standards were compared by means of a temperature-controlled optical trap...

متن کامل

Measurement Error of Voltage Responsivity of Pyroelectric Detector Induced by Use of Non-Sinusoidal Modulation of Radiation

Abstract. For the experimental measurements of pyroelectric detectors voltage responsivity, sinusoidal modulated optical radiation should be used. In practice, optical choppers are commonly used in experimental set-ups to modulate optical source and as a result optical radiation may have a square or trapezoidal waveform. In the paper, the frequency dependence of voltage responsivity of pyroelec...

متن کامل

Quantum modeling of light absorption in graphene based photo-transistors

Graphene based optical devices are highly recommended and interested for integrated optical circuits. As a main component of an optical link, a photodetector based on graphene nano-ribbons is proposed and studied. A quantum transport model is presented for simulation of a graphene nano-ribbon (GNR) -based photo-transistor based on non-equilibrium Green’s function method. In the proposed model a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009