Closure Devices for Patent Foramen Ovale and Atrial Septal Defects
ثبت نشده
چکیده
©2014 Blue Cross and Blue Shield of Louisiana An independent licensee of the Blue Cross and Blue Shield Association No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, or otherwise, without permission from Blue Cross and Blue Shield of Louisiana. Page 1 of 13 Applies to all products administered or underwritten by Blue Cross and Blue Shield of Louisiana and its subsidiary, HMO Louisiana, Inc.(collectively referred to as the “Company”), unless otherwise provided in the applicable contract. Medical technology is constantly evolving, and we reserve the right to review and update Medical Policy periodically.
منابع مشابه
Selecting the optimal closure device in patients with atrial septal defects and patent foramen ovaleD
Patent foramen ovale and atrial septal defects are common cardiac defects that can be routinely closed with transcatheter devices, rather than more invasive open surgical techniques. There is good evidence supporting both surgical and transcatheter closure of atrial septal defects, but there remains controversy regarding some of the currently applied indications for patent foramen ovale closure...
متن کاملRecent advances in closure of atrial septal defects and patent foramen ovale
Transcatheter closure of secundum atrial septal defect (ASD) and patent foramen ovale (PFO) is now widely accepted as an alternative to surgical closure. With currently available devices and techniques, approximately 80-90% of secundum ASDs and all PFOs can be closed percutaneously. While many devices are available, the use of any particular device is dictated largely by individual defect anato...
متن کاملPatent Foramen Ovale and Atrial Septal Defect: Diagnosis and Therapy
Patent foramen ovale (PFO) and atrial septal defect (ASD) are frequent congenital heart defects in adults. While the indication for surgical or interventional closure of an ASD is sufficiently evaluated, the necessity of closing a PFO remains a topic of academic discussions. In this article we present epidemiological data, show the actual anatomic classification, highlight relevant aspects of p...
متن کاملHistorical Aspects of Transcatheter Occlusion of Atrial Septal Defects
Following the description of surgical closure of atrial septal defect (ASD) in early 1950s (Bigelow et al., 1950; Lewis et al., 1953; Gibbon, 1953), it rapidly became a standard therapy of ASDs. Surgical closure of ostium secundum ASDs is safe and effective with negligible mortality (Murphy et al., 1990; Galal et al., 1994; Pastorek et al., 1994), but the morbidity associated with sternotomy/th...
متن کاملIs closure recommended for patent foramen ovale and cryptogenic stroke? Patent foramen ovale in cryptogenic stroke: not to close.
A quick PubMed search reveals an abundance of editorials, reviews, and opinion pieces on the subject of patent foramen ovale (PFO) management, and this is now the fourth published article on this topic that has adapted William Shakespeare’s classic words from Hamlet to describe the conundrum that faces neurologists, cardiologists, and their patients.1–3 The degree to which this title has been o...
متن کاملPacemaker lead entrapment complicating transcatheter closure of a patent foramen ovale.
T ranscatheter cardiovascular interventions are nowadays more frequently and safely performed, thus leading to populate the heart with medical devices. Here, we describe an unusual complication following percutaneous closure of a patent foramen ovale (PFO) with an atrial septal occluder. A 52-year-old woman with history of transient ischemic attack was found to have a PFO associated with an atr...
متن کامل