MRI with zero echo time: hard versus sweep pulse excitation.

نویسندگان

  • Markus Weiger
  • Klaas P Pruessmann
  • Franciszek Hennel
چکیده

Zero echo time can be obtained in MRI by performing radiofrequency (RF) excitation as well as acquisition in the presence of a constant gradient applied for purely frequency-encoded, radial centre-out k-space encoding. In this approach, the spatially nonselective excitation must uniformly cover the full frequency bandwidth spanned by the readout gradient. This can be accomplished either by short, hard RF pulses or by pulses with a frequency sweep as used in the SWIFT (Sweep imaging with Fourier transform) method for improved performance at limited RF amplitudes. In this work, the two options are compared with respect to T2 sensitivity, signal-to-noise ratio (SNR), and SNR efficiency. In particular, the SNR implications of sweep excitation and of initial or periodical acquisition gaps required for transmit-receive switching are investigated. It was found by simulations and experiments that, whereas equivalent in terms of T2 sensitivity, the two techniques differ in SNR performance. With ideal, ungapped simultaneous excitation and acquisition, the sweep approach would yield higher SNR throughout due to larger feasible flip angles. However, acquisition gapping is found to take a significant SNR toll related to a reduced acquisition duty cycle, rendering hard pulse excitation superior for sufficient RF amplitude and also in the short-T2 limit.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Imaging Pseudo-Echoes Produced by a Frequency-Swept Pulse

J-Y. Park, M. Garwood Center for Magnetic Resonance Research and Department of Radiology, University of Minnesota, Minneapolis, MN, United States Synopsis: Frequency-swept pulses, like the hyperbolic secant (HS1) pulse, are not typically employed for excitation in MRI. When used for excitation in gradient-echo imaging, the HS1 pulse does not produce a proper echo because the magnetization phase...

متن کامل

ZTE imaging with enhanced flip angle using modulated excitation.

PURPOSE Zero echo time (ZTE) imaging is a fast, robust, and silent three-dimensional technique for direct MRI of tissues with rapid transverse relaxation. It is conventionally performed with hard, block-shaped excitation pulses short enough to excite spins uniformly over a large bandwidth. With this approach, the achievable flip angle (FA) is limited by the available B1 amplitude. The purpose o...

متن کامل

Simultaneous Short T2 Excitation and Long T2 Suppression RF Pulses

Introduction: Ultrashort echo time (UTE) MRI requires specialized pulse sequences to overcome the short T2 relaxation of the MR signal encountered in tissues such as ligaments, tendon or cortical bone. Imaging short T2 tissues is achieved in UTE by acquiring the Free Induction Decay (FID) of the MR signal as soon after the end of the RF excitation pulse as possible. This is typically accomplish...

متن کامل

Improved 3D Spin-Echo Imaging Using Frequency-Swept Pulses

J-Y. Park, O. H. Gröhn, M. Garwood Center for Magnetic Resonance Research and Department of Radiology, University of Minnesota, Minneapolis, MN, United States, A.I.Virtanen Institute for Molecular Sciences, University of Kuopio, Kuopio, Finland Introduction: Frequency-modulated (FM) pulses, including adiabatic full-passage (AFP) pulses, are sometimes preferred for selective refocusing in spin-e...

متن کامل

MR Physics & Techniques for Clinicians: Spin Echo Imaging

Spin echo imaging is often called the workhorse of MRI as it is frequently a large part of many clinical protocols. By definition, the “spin echo” is the occurrence of transverse magnetization that has been re-phased by a refocusing RF pulse. Note that transverse magnetization exists following an excitation RF pulse that tips the magnetization from the equilibrium, longitudinal direction into t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 66 2  شماره 

صفحات  -

تاریخ انتشار 2011