Relationship between esophageal and alveolar pressure variations-during occlusion.

نویسنده

  • R Peslin
چکیده

To the Editor: Failure of mouth pressure variations (APm) to reflect alveolar pressure variations (APA) during thoracic gas volume (TGV) measurements by Boyle’s law has been reported in asthmatic patients by Shore and Martin (1) and quite recently by Stanescu et al. (2). In both studies the conclusions were reached by comparing TGV’s obtained by relating plethysmographic volume changes (AVbox) to APm (TGVm = AVbox/APm) and by relating them to pressure variations in the esophagus (TGVes = AVbox/APes), taken to represent pleural pressure variations (APpl). How close APpl is to APA is the question. It has been discussed by Stanescu et al. (2) on the basis of a monoalveolar model featuring lung and airways properties, including the compliance of intrathoracic airway walls and the shunt impedance of the upper airways. This model study showed that for normal compliances of lung tissue (CL), alveolar gas (Cg), intrathoracic airway wall (CB), and extrathoracic airway wall (CE), APpl was only 3% larger than APA at a frequency of 2 Hz. Moreover APP~/APA, in contrast with APm/APA, was not substantially modified by increasing peripheral and central airway resistance and by decreasing the impedance of extrathoracic airway walls. Having made similar computer simulation both with the same and with a two-compartment model, I would like to add a few points. Monoalveolar model. In static conditions, i.e., at infinitely low panting frequency, APpl and APA are in phase and AP~~/APA = 1 + (Cg + CE)/(CL + CB). It may be seen that APpl may be substantially larger than APA when Cg is large and CL is small (when specific lung compliance is low, e.g., at high lung volume in normal subjects). AP~~/APA is also directly related to upper airway wall compliance (CE). Although the relationship between APpl and APA is given by a high-order differential equation, their amplitude ratio and phase angle (+) may be predicted to vary little with the panting frequency. In all the situations examined by Stanescu et al. (2) and up to 4 Hz, APpl/ APA does not differ by more than 1% from its static value, as given above, and I+] is less than 1". Bialveolar model. I assumed that the lung was made of two compartments arranged in parallel, each with its tissue compliance (Cl, C,), gas compliance (Cgl, Cgz), and airway resistance (RI, Rz). Tissue resistances and airway walls compliances were neglected. In such a model APA will not be the same in the two compartments (APA~ # APA~) except in static conditions or when their specific compliances are equal (CJCg, = CJCgz). The accuracy of TGVes will depend on the ability of APpl to reflect the weighted average of local APA [APA = (APA~. Cg, + APA~. Cg2)/(Cg, + Cgz)]. The relationship between APpl and APA is given by the differential equation

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relationship Between Esophageal and Alveolar Pressure Variations During Occlusion

To the Editor: Failure of mouth pressure variations (APm) to reflect alveolar pressure variations (APA) during thoracic gas volume (TGV) measurements by Boyle’s law has been reported in asthmatic patients by Shore and Martin (1) and quite recently by Stanescu et al. (2). In both studies the conclusions were reached by comparing TGV’s obtained by relating plethysmographic volume changes (AVbox) ...

متن کامل

Relationship between Anatomical Variations of Sinonasal Area and Maxillary Sinus Pneumatization

Introduction: Maxillary sinuses are among the largest paranasal sinuses with various shapes and volumes. The dimensions and volumes of maxillary sinuses play an important role in the surgical treatment plan. The higher levels of pneumatization of alveolar bone lead to the increase of odontogenic sinusitis which cause problems in dental implantation. Therefore, this study aimed to evaluate...

متن کامل

Optimal esophageal balloon volume for accurate estimation of pleural pressure at end-expiration and end-inspiration: an in vitro bench experiment

BACKGROUND Esophageal pressure, used as a surrogate for pleural pressure, is commonly measured by air-filled balloon, and the accuracy of measurement depends on the proper balloon volume. It has been found that larger filling volume is required at higher surrounding pressure. In the present study, we determined the balloon pressure-volume relationship in a bench model simulating the pleural cav...

متن کامل

Do spontaneous and mechanical breathing have similar effects on average transpulmonary and alveolar pressure? A clinical crossover study.

BACKGROUND Preservation of spontaneous breathing (SB) is sometimes debated because it has potentially both negative and positive effects on lung injury in comparison with fully controlled mechanical ventilation (CMV). We wanted (1) to verify in mechanically ventilated patients if the change in transpulmonary pressure was similar between pressure support ventilation (PSV) and CMV for a similar t...

متن کامل

Changes in blood pressure and heart rhythm during transhiatal esophagectomy

Background: Esophagectomy is considered to be the main treatment for esophageal malignancies. Among the different methods, transhiatal approach can cause less damage to patients and is widely used however, manipulation of esophagus result in heart rate and blood pressure variations. The aim of this study was to investigate changes in blood pressure and heart rhythm during transhiatal esophagect...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology: respiratory, environmental and exercise physiology

دوره 54 4  شماره 

صفحات  -

تاریخ انتشار 1983