Sensitivity and Removed THD of a Phase- Cutting Dimmer

نویسنده

  • H. Fathabadi
چکیده

In this paper, we consider a designed and implemented phase-cutting dimmer. In fact, the dimmer is closed loop and a microcontroller calculates and then regulates the firing delay angles of each channel. Depending on the firing angle, the harmonic distortion in the input current will not comply with international standards, such as IEC 61000-3-2 (class C equipments). For solving this problem, eight harmonic compensators have been added to the dimmer. So, the proposed dimmer has a little harmonic distortion in the input current whereas conventional phase-cutting dimmers are not so. Sensitivity and removed THD of the proposed dimmer will be presented. Keywords—Dimmer, compensator, harmonic, dimming.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reduction of Harmonic in phase-cutting Dimmers

In this paper, we consider a designed and implemented dimmer. The dimmer is closed loop and phasecutting type. In fact, a microcontroller calculates and then regulates the firing delay angles of eight triacs. Depending on the firing angle, the harmonic distortion in the input current will not comply with international standards, such as IEC 61000-3-2(class C equipments). For solving this proble...

متن کامل

A Hybrid Switching Technique for Single-Phase AC-Module PV System to Reduce Power Losses and Minimize THD

This paper proposes a hybrid switching technique for a domestic PV system with AC-module architecture. In this PV system, independent control of PV modules, which are directly connected to DC terminals of a single-phase cascaded multilevel inverter, makes module-level MPPT possible to extract maximum available solar energy, especially in partial shading conditions. As one of the main contributi...

متن کامل

Design of a Digital Voltage Controller in Single-Phase Grid-Connected Renewable Converters

Power decoupling of pulsating grid side power from constant source side power is one of the paramount issues in single phase-phase grid-connected renewable systems. The principal aim of such systems is the decrease of the capacitance of the decoupled capacitor. However, this causes some problems such as an increase in the total harmonic distortion (THD) of injected current to the grid and bus v...

متن کامل

Performance Investigation of Multi-Phase VSI with Simple PWM Switching Techniques

This paper presents the performance investigation of multi-phase voltage source inverter (VSI) with simple PWM switching techniques namely the harmonic injection and offset injection method. The technique discussed in this paper is easy to implement and avoid complicated controlling algorithm adapted in SVPWM technique. A generalized algorithm suitable for odd number of phases is developed in M...

متن کامل

THD Minimization on the Line-to-Line Voltage of Multilevel Inverters

In this paper, minimization of the total harmonics (THD) present in the output voltage of multilevel inverters is discussed . In order to reduce the harmonic contents of the inverter's output voltage the best approach is THD minimization. In multilevel inverters, if fundamental frequency switching strategy is considered,(each switch turning on and off once per output cycle), the switching angle...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -