Squeezed-input, optical-spring, signal-recycled gravitational-wave detectors

نویسندگان

  • Jan Harms
  • Yanbei Chen
  • Simon Chelkowski
  • Alexander Franzen
  • Henning Vahlbruch
  • Karsten Danzmann
چکیده

We theoretically analyze the quantum noise of signal-recycled laser interferometric gravitational-wave detectors with additional input and output optics, namely frequency-dependent squeezing of the vacuum state of light entering the dark port and frequency-dependent homodyne detection. We combine the work of Buonanno and Chen on the quantum noise of signal-recycled interferometers with ordinary input and output optics, and the work of Kimble el al. on frequency-dependent input and output optics with conventional interferometers. Analytical formulas for the optimal input and output frequency dependencies are obtained. It is shown that injecting squeezed light with the optimal frequency-dependent squeezing angle into the dark port yields an improvement on the noise spectral density by a factor of e (in power) over the entire squeezing bandwidth, where r is the squeezing parameter. It is further shown that frequency-dependent (variational) homodyne read-out leads to an additional increase in sensitivity which is significant in the wings of the doubly resonant structure. The optimal variational input squeezing in case of an ordinary output homodyne detection is shown to be realizable by applying two optical filters on a frequency-independent squeezed vacuum. Throughout this paper, we take as example the signal-recycled topology currently being completed at the GEO 600 site. However, theoretical results obtained here are also applicable to the proposed topology of Advanced LIGO.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sensitivity of intracavity filtering schemes for detecting gravitational waves

We consider enhancing the sensitivity of future gravitational-wave detectors by adding optical filters inside the signal-recycling cavity—an intracavity filtering scheme, which coherently feeds the sideband signal back to the interferometer with a proper frequency-dependent phase. We study three cases of such a scheme with different motivations: (i) the case of backaction noise evasion, trying ...

متن کامل

Squeezed Light for the Interferometric Detection of High Frequency Gravitational Waves

The quantum noise of the light field is a fundamental noise source in interferometric gravitational wave detectors. Injected squeezed light is capable of reducing the quantum noise contribution to the detector noise floor to values that surpass the so-called Standard-Quantum-Limit (SQL). In particular, squeezed light is useful for the detection of gravitational waves at high frequencies where i...

متن کامل

Experimental demonstration of a squeezing-enhanced power-recycled michelson interferometer for gravitational wave detection.

Interferometric gravitational wave detectors are expected to be limited by shot noise at some frequencies. We experimentally demonstrate that a power recycled Michelson with squeezed light injected into the dark port can overcome this limit. An improvement in the signal-to-noise ratio of 2.3 dB is measured and locked stably for long periods of time. The configuration, control, and signal readou...

متن کامل

Sagnac Interferometer as a Speed-Meter-Type, Quantum-Nondemolition Gravitational-Wave Detector

According to quantum measurement theory, “speed meters” — devices that measure the momentum, or speed, of free test masses — are immune to the standard quantum limit (SQL). It is shown that a Sagnac-interferometer gravitational-wave detector is a speed meter and therefore in principle it can beat the SQL by large amounts over a wide band of frequencies. It is shown, further, that, when one igno...

متن کامل

Scaling law in signal recycled laser-interferometer gravitational-wave detectors

By mapping the signal-recycling (SR) optical configuration to a three-mirror cavity, and then to a single detuned cavity, we express SR optomechanical dynamics, input–output relation and noise spectral density in terms of only three characteristic parameters: the (free) optical resonant frequency and decay time of the entire interferometer, and the laser power circulating in arm cavities. These...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003