Millimeter-wave achromatic half-wave plate.
نویسندگان
چکیده
We have constructed an achromatic half-wave plate (AHWP) suitable for the millimeter wavelength band. The AHWP was made from a stack of three sapphire a-cut birefringent plates with the opticalaxes of the middle plate rotated by 50.5 deg with respect to the aligned axes of the other plates. The measured modulation efficiency of the AHWP at 110 GHz was 96 +/- 1.5%. In contrast, the modulation efficiency of a single sapphire plate of the same thickness was 43 +/- 4%. Both results are in close agreement with theoretical predictions. The modulation efficiency of the AHWP was constant as a function of incidence angles between 0 and 15 deg. We discuss design parameters of an AHWP in the context of astrophysical broadband polarimetry at the millimeter wavelength band.
منابع مشابه
A Millimeter-Wave Achromatic Half Wave Plate
We have constructed an achromatic half wave plate (AHWP) suitable for the millimeter wavelength band. The AHWP was made from a stack of three sapphire a-cut birefringent plates with the optical axes of the middle plate rotated by 50.5 degrees with respect to the aligned axes of the other plates. The measured modulation efficiency of the AHWP at 110 GHz was 96 ± 1.5%. In contrast, the modulation...
متن کاملTerahertz achromatic quarter-wave plate.
Phase retarders usually present a strong frequency dependence. We discuss the design and characterization of a terahertz achromatic quarter-wave plate. This wave plate is made from six birefringent quartz plates precisely designed and stacked together. Phase retardation has been measured over the whole terahertz range by terahertz polarimetry. This achromatic wave plate demonstrates a huge freq...
متن کاملPerformance of three- and five-stack achromatic half-wave plates at millimeter wavelengths.
We study the performance of achromatic half-wave plates (AHWPs) as a function of the detection bandwidth of a power detector operating in the millimeter wave band and the spectral shape of the incident radiation. We focus particular attention on the extraction of the degree of incident polarization and its orientation angle from the intensity measured as a function of AHWP rotation angle, which...
متن کاملAnalysis of performance of three- and five-stack achromatic half-wave plates at millimeter wavelengths
We study the performance of achromatic half-wave plates (AHWP) as a function of their construction parameters, the detection bandwidth of a power detector operating in the millimeter wave band, and the spectral shape of the incident radiation. We focus particular attention on the extraction of the degree of incident polarization and its orientation angle from the intensity measured as a functio...
متن کاملDesign and laboratory demonstration of an achromatic vector vortex coronagraph.
A vector vortex coronagraph (VVC) is one of promising means for imaging extremely faint objects around bright stars such as exoplanets. We present a design of an achromatic VVC, in which an axially-symmetric half-wave plate (AHP) is placed between crossed polarization filters (circular polarizer and analyzer). The circular polarizer and the analyzer are both composed of a polarizer and a quarte...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied optics
دوره 44 22 شماره
صفحات -
تاریخ انتشار 2005