Comparison of seven serum assays on four automatic analysers

نویسندگان

  • Lucia Sacchetti
  • Dionigio Cerasuolo
  • Marco Besozzi
  • Antonio D'Agostino
  • Carlo Franzini
  • Francesco Salvatore
چکیده

Serum enzyme assays used on four different analysers (Hitachi 737, Hitachi 705, Cobas-bio and RA-2X) were compared by determining the activity of seven different enzymes (AST, ALT, LD, ALP, GGT, CK and AMS). Performance checks (quality control procedure) and replications (the study of the total analytic imprecision and of its components) were conducted and the methods were compared by linear regression analysis with statistical inference on the curves following the protocols of the National Committee for Clinical Laboratory Standards (NCCLS: PSEP- 2, PSEP-3, PSEP-4). The correlation coefficients between the methods (r = 0.991-0.999), together with the other statistical parameters, indicated that the methods are well correlated on all the instruments. The total imprecision was good for all analytes, except ALT. Among the instruments tested, the RA-2X gave more variable results, although the total imprecision was acceptable. There was no relevant carry-over effect. The evaluation of performance claims indicated that the expected error did not substantially affect the results at the level of clinical decisions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

HUMAN IgG SUBCLASS LIQUID REAGENT KITS

In normal adults, IgG constitutes approximately 75% of the total serum immunoglobulins. Within the IgG class, the usual order of concentration of the 4 subclasses is IgG1> IgG2> IgG3> IgG4, but the actual concentration of each may vary markedly between individuals. The four IgG subclasses show considerable differences in their properties, including ability to fix complement, to bind to macropha...

متن کامل

Assessment of recently developed blood gas analysers: a multicentre evaluation

Providing guidelines for testing expected inaccuracy and imprecision is still a matter under debate. The Expert Panel of the French Society of Clinical Chemistry has developed a protocol, which was based on a comparative multi-centre evaluation of four instruments: the Ciba-Corning 278, the Instrumentation Laboratory 1306, the Nova SP 5 and the ABL 330. The purpose was to evaluate the analytica...

متن کامل

The Correlation of Machine Translation Evaluation Metrics with Human Judgement on Persian Language

Machine Translation Evaluation Metrics (MTEMs) are the central core of Machine Translation (MT) engines as they are developed based on frequent evaluation. Although MTEMs are widespread today, their validity and quality for many languages is still under question. The aim of this research study was to examine the validity and assess the quality of MTEMs from Lexical Similarity set on machine tra...

متن کامل

Special problems of cost analysis and cost-benefit analysis as applied to large multi-test analysers

Special problems of cost analysis and cost-benefit analysis as applied to large multi-test analysers

متن کامل

Vermasvuori, Mikko; Vatanski, Nikolai; Jämsä-Jounela, Sirkka-Liisa DATA BASED FAULT DETECTION OF THE ONLINE ANALYSERS IN A DEAROMATISATION PROCESS

Fault diagnosis methods based on process history data have been studied widely in recent years, and several successful industrial applications have been reported. In this paper a comparison of four monitoring methods, PCA, PLS, subspace identification and self-organising maps, for fault detection of the online analysers in a dearomatisation process is presented. The effectiveness of different s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of Automatic Chemistry

دوره 11  شماره 

صفحات  -

تاریخ انتشار 1989