Physiological responses to exercise on different models of the concept II rowing ergometer.

نویسندگان

  • Andrew J Vogler
  • Anthony J Rice
  • Robert T Withers
چکیده

PURPOSE The Concept II model C (IIC) rowing ergometer was replaced by the Concept II model D (IID), but the design modifications of the updated ergometer might alter resistance characteristics and rowing technique, thereby potentially influencing ergometer test results. This study evaluated the physiological response to rowing on the IIC and IID ergometers during a submaximal progressive incremental test and maximal-performance time trial. METHODS Eight national-level rowers completed submaximal and maximal tests on the IIC and IID ergometers separated by 48 to 72 h. Physiological responses and calculated blood lactate thresholds (LT1 and LT2) were compared between ergometer models (IIC vs IID) using standardized drag-factor settings. RESULTS Power output, oxygen consumption, rowing economy (mL O2 . min-1 . W-1), heart rate, blood lactate concentration, stroke rate, and rating of perceived exertion all displayed similar responses regardless of ergometer model. Calculated physiological values equivalent to LT1 and LT2 were also similar between models, except for blood lactate concentration at LT, which displayed a small but statistically significant difference (P = .02) of 0.2 mmol/L. CONCLUSIONS The physiological response when rowing on IIC and IID ergometers is nearly identical, and testing can therefore be carried out on either ergometer and the results directly compared.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Scaling concept II rowing ergometer performance for differences in body mass to better reflect rowing in water.

We investigated whether the concept II indoor rowing ergometer accurately reflects rowing on water. Forty-nine junior elite male rowers from a Great Britain training camp completed a 2000 m concept II model C indoor rowing ergometer test and a water-based 2000 m single-scull rowing test. Rowing speed in water (3.66 m/s) was significantly slower than laboratory-based rowing performance (4.96 m/s...

متن کامل

Comparison of rowing on a concept 2 stationary and dynamic ergometer.

Biomechanical and physiological responses to rowing 1000 m at a power output equivalent to a 2000 m race were compared in 34 collegiate rowers (17 women, 17 men) rowing on a stationary and dynamic Concept 2 ergometer. Stroke ratio, peak handle force, rate of force development, impulse, and respiratory exchange ratio decreased by 15.7, 14.8, 10.9, 10.2 and 1.9%, respectively, on the dynamic ergo...

متن کامل

Reliability of power output during rowing changes with ergometer type and race distance.

Coaches, sport scientists and researchers assess rowing performance on-water and on a variety of ergometers. Ergometers are frequently used because of the easier assessment environment. However, there is limited information on the ability of rowers to reproduce mean power or time-trial time when using different rowing ergometers (Concept II and RowPerfect) or completing tests over different dis...

متن کامل

Pulmonary O2 uptake on-kinetics in rowing and cycle ergometer exercise.

The purpose of this study was to characterise, for the first time, the pulmonary O2 uptake (V(O2)) on-kinetic responses to step transitions to moderate and heavy intensity rowing ergometer exercise, and to compare the responses to those observed during upright cycle ergometer exercise. We hypothesised that the recruitment of a greater muscle mass in rowing ergometer exercise (Row) might limit m...

متن کامل

Ventilatory threshold characterizations during incremental rowing and cycling exercises in older subjects.

In order to individualize the intensity of an aerobic training program on different ergometers in healthy elderly subjects using a single test of muscular exercise, we analysed cardiorespiratory responses in 8 men (65.7 +/- 4.5 yrs) and 10 women (63.3 +/- 4.8 yrs). The heart rate corresponding to the ventilatory threshold was defined as individualised exercise intensity. All subjects carried ou...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International journal of sports physiology and performance

دوره 2 4  شماره 

صفحات  -

تاریخ انتشار 2007