Location Registration and Recognition (LRR) for Longitudinal Evaluation of Corresponding Regions in CT Volumes

نویسندگان

  • Michal Sofka
  • Charles V. Stewart
چکیده

The algorithm described in this paper takes (a) two temporally-separated CT scans, I1 and I2, and (b) a series of locations in I1, and it produces, for each location, an affine transformation mapping the locations and their immediate neighborhood from I1 to I2. It does this without deformable registration by using a combination of feature extraction, indexing, refinement and decision processes. Together these essentially "recognize" the neighborhoods. We show on lung CT scans that this works at near interactive speeds, and is at least as accurate as the Diffeomorphic Demons algorithm. The algorithm may be used both for diagnosis and treatment monitoring.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimization of clinical target volume delineation using magnetic resonance spectroscopic imaging (MRSI) in 3D conformal radiotherapy of prostate cancer

Background: For the purpose of individual clinical target volume assessment in radiotherapy of prostate cancer, MRSI was used as a molecular imaging modality with MRI and CT images. Materials and Methods: The images of 20 prostate cancer patients were used in this study. The MR and MRSI images were registered with CT ones using non-rigid registration technique. The CT based planning (BP), CT/MR...

متن کامل

The Role of MRSI in Target Volume Definition for Radiation Therapy of Prostate Cancer

Introduction: Recently, magnetic resonance spectroscopic imaging (MRSI), as a functional imaging method, has been used for clinical target volume definition. In this study, we used this method to define the target volume in prostate radiotherapy. Material and Method: In this study, we used images of 20 prostate cancer cases. MRSI and MRI images were fused with CT images. Then, treatment plannin...

متن کامل

A protocol to extend the longitudinal coverage of on‐board cone‐beam CT

The longitudinal coverage of a LINAC-mounted CBCT scan is limited to the corresponding dimensional limits of its flat panel detector, which is often shorter than the length of the treatment field. These limits become apparent when fields are designed to encompass wide regions, as when providing nodal coverage. Therefore, we developed a novel protocol to acquire double orbit CBCT images using a ...

متن کامل

New Pseudo-CT Generation Approach from Magnetic Resonance Imaging using a Local Texture Descriptor

Background: One of the challenges of PET/MRI combined systems is to derive an attenuation map to correct the PET image. For that, the pseudo-CT image could be used to correct the attenuation. Until now, most existing scientific researches construct this pseudo-CT image using the registration techniques. However, these techniques suffer from the local minima of the non-rigid deformation energy f...

متن کامل

Location registration and recognition (LRR) for serial analysis of nodules in lung CT scans

In the clinical workflow for lung cancer management, the comparison of nodules between CT scans from subsequent visits by a patient is necessary for timely classification of pulmonary nodules into benign and malignant and for analyzing nodule growth and response to therapy. The algorithm described in this paper takes (a) two temporally-separated CT scans, I(1) and I(2), and (b) a series of nodu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention

دوره 11 Pt 2  شماره 

صفحات  -

تاریخ انتشار 2008