چکیده

OBJECTIVES The purpose of this study was to evaluate the safety of implanting a cardiac resynchronization therapy (CRT) system. BACKGROUND Clinicians and patients require data on the safety of the CRT implant procedure to estimate procedural risk. METHODS We evaluated outcomes of transvenous CRT system implantation in 2,078 patients from the Multicenter InSync Randomized Clinical Evaluation (MIRACLE) study, the MIRACLE Implantable Cardioverter-Defibrillator (ICD) study, and the InSync III study. We compared the MIRACLE study to the InSync III study and the MIRACLE ICD study randomized phase to its general phase to evaluate the effect of new technologies. RESULTS The implant attempt succeeded in 1,903 of 2,078 (91.6%) patients. Implant time decreased from 2.7 h in the MIRACLE study to 2.3 h in the InSync III study (p < 0.001), and from 2.8 h in the MIRACLE ICD study randomized phase to 2.4 h in the general phase (p < 0.001). The implant procedure produced 62 perioperative complications in 53 (9.3%) MIRACLE trial patients; 159 in 135 (21.1%) MIRACLE ICD study randomized phase patients and 71 in 62 (13.9%) general phase patients (p < 0.05 vs. randomized); and 41 in 37 (8.8%) InSync III study patients (p = NS vs. the MIRACLE study). We observed 73 postoperative complications in 62 (11.7%) MIRACLE trial patients, 77 in 68 (11.9%) MIRACLE ICD study randomized phase patients and 56 in 45 (11.0%) general phase patients (p = NS), and 37 in 34 (8.6%) InSync III study patients (p = NS). A total of 8% of patients required reoperation to treat lead dislodgement, extracardiac stimulation, or infection during follow-up. CONCLUSIONS Transvenous CRT system implantation appears safe, well-tolerated, has a high success rate, and improves with operator experience and the addition of new technologies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Implantation of cardiac resynchronization therapy systems in the CARE-HF trial: procedural success rate and safety.

AIMS To assess procedural characteristics and adjudicated procedure-related (<or=30 days) major adverse events among patients who underwent cardiac resynchronization therapy (CRT) implantation in the CARE-HF study. The CARE-HF study shows that CRT improves symptoms and reduces morbidity and mortality in New York Heart Association (NYHA) class III/IV chronic heart failure (CHF) patients. However...

متن کامل

Simple and effective solution for diaphragm pacing by that uses the transvenous femoral approach in a patient treated with cardiac resynchronization-defibrillator therapy: The wrapping method

The use of cardiac resynchronization therapy (CRT) has become widespread in patients with heart failure who meet the criteria for implantation. Coronary sinus lead positioning is important to provide the intended biventricular stimulation. Diaphragm pacing is a lead-related complication which occurs secondary to phrenic nerve stimulation. We present the case of a 58-year-old male patient who ha...

متن کامل

Heart Failure Predictors of Response to Cardiac Resynchronization Therapy in the Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy (MADIT-CRT)

Background—We hypothesized that combined assessment of factors that are associated with favorable reverse remodeling after cardiac resynchronization-defibrillator therapy (CRT-D) can be used to predict clinical response to the device. Methods and Results—The study population comprised 1761 patients enrolled in the Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchroniza...

متن کامل

Cardiac resynchronization therapy is more effective in women than in men: the MADIT-CRT (Multicenter Automatic Defibrillator Implantation Trial with Cardiac Resynchronization Therapy) trial.

OBJECTIVES The purpose of this study was to investigate the factors related to sex-specific outcomes for death and heart failure events in the MADIT-CRT (Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy) trial. BACKGROUND In the MADIT-CRT trial, women seemed to achieve a better result from resynchronization therapy than men. METHODS All 1,820 pat...

متن کامل

Lead extraction: The road to successful cardiac resynchronization therapy.

BACKGROUND Still increasing life expectancy in patients with implanted devices and large number of leads more and more often induce the need to cure the treatment complications or to change especially to cardiac resynchronization therapy (CRT). In order to prevent further complications, the possibility of damaged or redundant leads extraction should be taken into consideration. The aim of the p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 46 12  شماره 

صفحات  -

تاریخ انتشار 2005