Estimation of body composition from bioelectrical impedance of body segments: comparison with dual-energy X-ray absorptiometry.

نویسندگان

  • S P Stewart
  • P N Bramley
  • R Heighton
  • J H Green
  • A Horsman
  • M S Losowsky
  • M A Smith
چکیده

In twenty-eight healthy subjects, ten men and eighteen women, with a range in body mass index (BMI) of 17.9-31.6 kg/m2 and an age range 20-60 years, body composition was estimated by dual-energy X-ray absorptiometry (DEXA), skinfold anthropometry (SFA) and bioelectrical impedance analysis (BIA) of the 'whole body' and body segments. In thirteen subjects muscle mass was also estimated by 24 h urinary creatinine excretion. The relationship between fat-free mass (FFM) determined by DEXA and the impedance index of each body segment (calculated as length2/impedance (Z)) was analysed. The strongest correlation was between FFM (DEXA) and height2/'whole-body' Z (ZW) (r 0.97 for the combined sexes, standard error of estimate (SEE) 2.72 kg). Separate prediction equations were found to be necessary for males and females when estimating FFM from BIA measurement of the arm (for men, r 0.93, SEE 1.98 kg; for women, r 0.75, SEE 2.87 kg). Muscle mass derived from 24 h creatinine excretion showed weak correlation with FFM (DEXA) (r 0.57, P = 0.03) and no correlation with FFM (SFA). FFM (SFA) correlated well with both FFM (DEXA) (r 0.96, SEE = 3.12 kg) and with height2/ZW (r 0.92, SEE 4.52 kg). Measurement of the impedance of the arm offers a simple method of assessing the composition of the whole body in normal individuals, and it appears comparable with other methods of assessment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Total body composition estimated by standing-posture 8-electrode bioelectrical impedance analysis in male wrestlers

Standing-posture 8-electrode bioelectrical impedance analysis is a fast and practical method for evaluating body composition in clinical settings, which can be used to estimate percentage body fat (BF%) and skeletal muscle mass in a subject's total body and body segments. In this study, dual-energy X-ray absorptiometry (DXA) was used as a reference method for validating the standing 8-electrode...

متن کامل

Relationships among dual-energy X-ray absorptiometry, bioelectrical impedance and ultrasound measurements of body composition of swine

In three separate studies (156 pigs total), dual-energy X-ray absorptiometry (DXA), bioelectrical impedance (BIA) and ultrasound were compared as methods for measuring live body composition of pigs at 60 and 100-110 kg BWt. DXA measured total body fat and lean content, BIA measurements of resistance (Rs) and reactance (Xc) were used to calculate total body lean mass and ultrasound measurements ...

متن کامل

[Formulation of an equation to predict fat mass using bioelectrical impedance in adults in a wide range of ages and body mass index].

BACKGROUND Bioelectrical impedance (BIA) has a good correlation and agreement with reference techniques, such as dual energy X-ray absorptiometry (DEXA), to assess body composition. AIM To develop and assess the concordance of an equation to predict body fat mass derived from anthropometric data, gender, age and resistance obtained from bioelectrical impedance in adults, using DEXA as the ref...

متن کامل

Comparison of Different Measurement Equations for Body Composition Estimation in Male Athletes

The purpose of this study was to compare the validity between three established prediction equations and our prediction equation referenced by DEXA (Dual-energy X-ray absorptiometry) on fat free mass (FFM) in Taiwan male soccer players. Methods: Twenty seven elite Taiwan soccer players were estimated by bioelectrical impedance analysis (BIA) and DEXA. The R2 value of FFM estimated by our predic...

متن کامل

Segmental body composition assessed by bioelectrical impedance analysis and DEXA in humans.

The present study assessed the relative contribution of each body segment to whole body fat-free mass (FFM) and impedance and explored the use of segmental bioelectrical impedance analysis to estimate segmental tissue composition. Multiple frequencies of whole body and segmental impedances were measured in 51 normal and overweight women. Segmental tissue composition was independently assessed b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of nutrition

دوره 69 3  شماره 

صفحات  -

تاریخ انتشار 1993