Comparison of macroscopic one-layer over number 1 nylon suture vasovasostomy with the standard two-layer microsurgical procedure.
نویسندگان
چکیده
OBJECTIVE To compare the outcomes of macroscopic one-layer vasovasostomy (MOLVV) with those of two-layer microsurgical vasovasostomy (TLMVV). METHODS Standard TLMVV was performed in 112 men (Group 1), while MOLVV was performed in 94 patients. All of the MOLVVs were performed with number 1 nylon suture as a temporary stent. The outcome measures were as follows: patency rate, pregnancy rate, operation time, total procedure cost, and complications. RESULTS The mean operation duration was 114 ± 10 min for the TLMVV technique, and 74 ± 5 min for the MOLVV procedure (P = 0.024). In patients who underwent vasal patency at 6-month postoperative period, the median sperm density (10⁶/mL) was 28.3 and 27.7 in Groups 1 and 2, respectively (P = 0.62). At the same time, the median total motile sperm count (× 10⁶) was 39.4 and 32.6 in two-layer microsurgical and one-layer macroscopic groups, respectively (P = 0.47). Patency rates were 82.1% in Group 1 and 77.7% in Group 2, which were not significantly different (P = 0.21). The pregnancy rate was 28.4% for patients in Group 1 and 26.7% for patients in Group 2 (P = 0.38). CONCLUSIONS There were no significant differences in terms of patency and pregnancy rates between MOLVV and TLMVV methods, but the MOLVV technique offers a decreased cost and operative time, and a simplified procedure.
منابع مشابه
Re: Comparison of vasovasostomy with conventional microsurgical suture and fibrin adhesive in rats.
We read with great interest the paper by Wilson F. Busato Junior and colleagues (1). In this elegant study two techniques of vasovasostomy have been tested in a laboratory setting. One group of rats underwent “conventional” one-layer anastomosis on the left vas deferent, after transection on the right side; another group was evaluated for a simplified anastomosis performed with one anchor point...
متن کاملComparison of vasovasostomy with conventional microsurgical suture and fibrin adhesive in rats.
OBJECTIVE Microsurgical procedures are currently the gold standard for vasovasostomy with excellent results, but it takes an increased operative time demanding special training and experience in microsurgery. The objective of this study is to reach the same results with reduced operative time. MATERIALS AND METHODS Male adults Wistar rats were divided into 3 groups: I) 20 rats in control grou...
متن کاملClinical Evaluation of Two Suture Pattern Techniques in Laparoscopic Gastrojejunostomy in Dog
Objectives-To evaluate the clinical safety and feasibility of one layer suture pattern technique in gastrojejunostomy in dog in comparison to two layer suture pattern technique. Study Design-Elective experimental study Animals-Sixteen mix-breed healthy male and female dogs Methods-Sixteen healthy male and female dogs were randomly divided in two groups. In the control group the two layer...
متن کاملTreatment of failed vasectomy reversal using a microsurgical two-layer anastomosis technique
OBJECTIVE To evaluate the application of a microsurgical two-layer anastomosis technique in the treatment of failed vasectomy reversal. METHODS A microsurgical two-layer anastomosis was used in a series of 24 patients with confirmed anastomotic obstruction after previous vasectomy reversal. The patients were followed up for 9 months to 6 years, and the efficacy of the procedure was evaluated ...
متن کاملFibrin glue assisted 3-suture vasovasostomy.
PURPOSE We report on the early results of fibrin glue assisted, 3-suture microsurgical vasovasostomy (FGV) technique in humans. MATERIALS AND METHODS After Institutional Review Board approval, 42 patients were enrolled prospectively from October 2002 to March 2004. Patients underwent microsurgical 3-suture vasovasostomy with completion of the anastomosis with fibrin sealant. Patient and partn...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Human fertility
دوره 16 3 شماره
صفحات -
تاریخ انتشار 2013