Correlation between end-tidal and arterial carbon dioxide partial pressure in patients undergoing craniotomy

نویسندگان

  • Naser Hemmati
  • Abdol Hamid Zokaei
  • Ali Karbasforooshan
چکیده

Background: Both end-tidal carbon dioxide pressure (ETCO2) is used routinely as an indicator of arterial partial pressure of carbon dioxide (PaCO2) and thus adequacy of ventilation. Accurate determination of the PaCO2 level in neuroanesthesia is quite important because of its effect on cerebral blood flow and also hyperventilation is often used to reduce intracranial pressure in neurosurgical patients. This study was aimed to evaluate the relationship between ETCO2 and arterial PaCO2 in neurosurgical patients undergoing craniotomy to assess the predictive value of ETCO2 as an indicator of PaCO2 level. Methods: Forty-five consecutive adult patients with inclusion criteria, scheduled to undergo elective craniotomy surgery were enrolled in this prospective study. Measurements of PaCO2 and ETCO2 were performed at three different intervals: Time 1: 10 min after induction of general anesthesia; time 2: after cranium opening prior to dural incision; and at time 3: start of dural closure. All patients received the same anesthetic agent (propofol, sufentanil, atracurium, oxygen). Data were initially analyzed using Pearson’s Correlation to assess the relationship between PaCO2 and ETCO2 at different stages of the operation. A p-value (P) of less than 0.05 was considered significant. The agreement between the measures of CO2 was assessed using Bland-Altman method, where mean difference and average between PaCO2 and ETCO2 were calculated. The 95% confidence intervals for the lower and upper limits of agreement were presented. . Results: A total of 44 patients, aged 18 to 65 years, ASA grades 1 and 2 were participated in the study. Mean difference, standard deviation and correlation coefficient of the parameters were calculated for three time periods. The values for PaCO2, ETCO2, (PaCO2ETCO2), and correlation coefficient for 10 min after anesthetic induction, prior to dural incision, and start of dural closure were 35.4 ± 3.2, 32.1 ± 3.2, 3.8 ± 2.1, and 0.565, 36.2 ± 3.1, 32.6 ± 3.2,4.8 ± 3.1, and 0.574, and 36.7 ± 2.4, 33 ± 3.2,3.8 ± 2.3, and 0.627, respectively (p less than 0.01 for all analyses). The greatest mean difference occurred just prior to dural incision. The lowest mean difference was observed at 10 min post-anesthetic induction. Conclusions: To the present study was aimed to correlate between End-tidal and arterial carbon dioxide partial pressure in neurosurgical patients undergoing craniotomy. Findings of this study showed that ETCO2 consistently underestimates the value of PaCO2 during craniotomy indicating that ETCO2 value can be used instead of PaCO2.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigating the Relationship Between End Tidal Carbon Dioxide and Arterial Carbon Dioxide Pressure in Patients With Respiratory Distress Referred to the Emergency Room of Hazrat Rasool Akram Hospital

Background: Measuring End-Tidal Carbon Dioxide (ETCO-2) can be a non-invasive, fast, and reliable method to predict partial pressure of carbon dioxide (PaCO2) in patients with respiratory distress. This method, which can be a suitable substitute to measure PaCO2, is being used in many emergency rooms and operating rooms in developed countries, but its exact relationship with PaCO2 has not been ...

متن کامل

بررسی همبستگی و میزان توافق نتایج PaCO2 گازهای خون شریانی با CO2 انتهای بازدمی (End-Tidal CO2) توسط کاپنوگرافی در بیماران مبتلا به تشدید حاد بیماری انسدادی ریوی (COPD)

  Background : Chronic Obstructive Pulmonary Disease (COPD) represents a major public health problem. The course of COPD is characterized by episodic periods of worsening symptoms, termed exacerbations. Supplemental oxygen should be given to patients with COPD exacerbation without causing CO2 retention. Arterial blood gas sampling is the gold standard for monitoring adequate oxygenation and for...

متن کامل

End-tidal Carbon Dioxide Measurements in Unintentional Non-Fire-Related Carbon Monoxide Poisoning

Background: Poisoning with carbon monoxide occurs occasionally worldwide, and the gold diagnostic standard is to measure carboxyhemoglobin level in the blood. This study investigated the correlation between carboxyhemoglobin and the end-tidal carbon dioxide levels in 50 patients with carbon monoxide poisoning. Methods: We recruited 50 volunteer patients who had been admitted to the Emergency S...

متن کامل

A study of partial pressure of arterial carbon dioxide and end-tidal carbon dioxide correlation in intraoperative and postoperative period in neurosurgical patients

BACKGROUND AND AIM Monitoring carbon dioxide (CO2) is of utmost importance in neurosurgical patients. It is measured by partial pressure of arterial CO2 (PaCO2) and end-tidal CO2 (ETCO2). We aimed to study the correlation between PaCO2 and ETCO2 in neurosurgical patients in the intraoperative and postoperative period on mechanical ventilation in Postanesthesia Care Unit (PACU). METHODOLOGY Th...

متن کامل

End-tidal to arterial carbon dioxide partial pressure difference during craniotomy in anaesthetised patients.

This study to evaluate the relationship between end-tidal carbon dioxide pressure (ETCO2) and arterial partial pressure of carbon dioxide (PaCO2) included 35 patients between the ages of 18 and 65 years, ASA grade 1 and 2, who had elective craniotomies. Measurements of PaCO2 and ETCO2 were taken simultaneously: 1) 10 minutes after induction of general anaesthesia, 2) after cranium opening prior...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2012