Investigation by isoelectric focusing of the initial carbohydrate-deficient transferrin (CDT) and non-CDT transferrin isoform fractionation step involved in determination of CDT by the ChronAlcoI.D. assay.
نویسندگان
چکیده
BACKGROUND The introduction of a new set of reagents for the determination of carbohydrate-deficient transferrin (CDT) as a marker of chronic alcohol abuse requires an independent evaluation of the analytic specificity of the test. This information is needed for correct interpretation and classification of test results. METHODS Isoelectric focusing on the PhastSystem(TM) followed by immunofixation, silver staining, and densitometry was used to validate the initial transferrin isoform fractionation step on anion-exchange microcolumns involved in the ChronAlcoI.D. assay. RESULTS The in vitro transferrin iron load was complete and stable. The CDT and non-CDT transferrin fractionation on anion-exchange microcolumns was reliable and reproducible (CV < or = 10%). Except for quantitatively unimportant traces of trisialo-Fe(2)-transferrin (<5% of total CDT), only asialo-, mono-, and disialo-Fe(2)-transferrin were detected in the microcolumn eluates (n = 170). There was a loss of proportionally similar amounts of asialo-Fe(2)-transferrin (during column rinsing) and disialo-Fe(2)-transferrin (on the anion exchanger). Thus, the peak height ratios for disialo- and asialo-Fe(2)-transferrin did not change from >1 (serum) to <1 (eluates) as described for the CDTect assays. The transferrin patterns in the ChronAlcoI.D. eluates were representative of those in serum. Transferrin D variants with isoelectric points close to that of trisialo-Fe(2)-transferrin C1 did not cause overdetermination of CDT by the ChronAlcoI.D. test. CONCLUSIONS The initial CDT and non-CDT fractionation step involved in determination of CDT by the ChronAlcoI.D. assay is efficient for eliminating non-CDT transferrins from serum before quantification of CDT in the final turbidimetric immunoassay. We recommend IEF for validation of other (commercial) CDT analysis methods and of odd CDT results.
منابع مشابه
Validation by isoelectric focusing of the anion-exchange isotransferrin fractionation step involved in determination of carbohydrate-deficient transferrin by the CDTect assay.
Serum concentration of carbohydrate-deficient transferrin (CDT) is used for laboratory diagnosis of chronic alcohol abuse. Using isoelectric focusing for validation of the initial isotransferrin fractionation step involved in the determination of CDT by the CDTect assay, we found a complete in vitro iron saturation of transferrin and sufficient stability of the transferrin iron load during colu...
متن کاملInterference of transferrin isoform types with carbohydrate-deficient transferrin quantification in the identification of alcohol abuse.
BACKGROUND Isoforms of transferrin interfere with measurement of carbohydrate-deficient transferrin (CDT) as a marker of heavy alcohol consumption. We evaluated the rate of inaccurate CDT results by immunoassays. METHODS We studied 2360 consecutive sera (1614 individuals) submitted for CDT assay without clinical information as well as samples from 1 patient with a congenital disorder of glyco...
متن کاملAllelic D variants of transferrin in evaluation of alcohol abuse: differential diagnosis by isoelectric focusing-immunoblotting-laser densitometry.
In the diagnosis of alcohol abuse transferrin (Tf) allelic D variants generate false-positive test results for carbohydrate-deficient transferrin (CDT) as assessed by their electrophoretic migration patterns. The predominant Tf C1 allele encodes a protein for which the most prevalent isoform has a pI of 5.4, i.e., four sialic acids and two bound ion molecules. Carriers of allele D encode Tfs wi...
متن کاملCan glycohemoglobin be used to assess glycemic control in patients with chronic renal failure?
false-positive results in S. pneumoniae cases because only the amount of CDT (a-to di-or trisialotransferrin) and/or the CDT/transferrin ratio is determined (19). HUS associated with S. pneumoniae therefore has to be considered in the diagnosis of primary and secondary defects in the glycan part of N-glycoproteins. The non-S. pneumoniae-associated HUS cases showed normal isoform distribution in...
متن کاملImproved capillary electrophoresis method for the determination of carbohydrate-deficient transferrin in patient sera.
Capillary zone electrophoresis (CZE) with a dynamic double coating formed by charged polymeric reagents represents an effective tool for the separation of iron-saturated transferrin (Tf) isoforms and thus the determination of carbohydrate-deficient transferrin (CDT, sum of asialo-, monosialo- and disialo-Tf in relation to total Tf) in human serum. Using the CEofix-CDT reagents, a 50 microm inne...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 46 4 شماره
صفحات -
تاریخ انتشار 2000