Focus Optimization of a Cryogenic Collimater Using Interferometric Measurements and Optical Modeling

نویسندگان

  • Joe Tansock
  • Alan Thurgood
  • Roy Esplin
چکیده

Space Dynamics Laboratory at Utah State University (SDL/IJSU) optimized the focus of an off-axis, cryogenically cooled infrared collimator for cryogenic operating temperatures. Historically, collimator focus was optimized at ambient temperatures where interactive focus adjustment and testing coulà be performed. The focus shift that occurred when the optics were cooled was minimized by collimator design, and the change was negligible compared to the spatial resolution of the IR sensor measuring the collimator's simulated point source. However, the focus determined at ambient temperature does not meet the image quality requirements of state-of-the-art sensors. The method used by SDL to determine optimal focus at cryogenic temperatures applies classical optical techniques to the cryogenically cooled environment. System level interferometric measurements are first made to characterize the system wavefront error. These measurements are then applied to an aberration-free optical model to evaluate system focus for a wavelength of 12 tim. The method also uses a knife edge test to refer the interferometric measurements to the aperture located near the focal point of the collimator. This paper discusses the physical test setup, outlines the optical model and analysis procedure, and presents results before and after focus optimization of a multifunction infrared calibrator.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cryogenic Q-factor measurement of optical substrates for optimization of gravitational wave detectors

Future generations of gravitational wave interferometers are likely to be operated at cryogenic temperatures because one of the sensitivity limiting factors of the present generation is the thermal noise of end mirrors and beam splitters that occurs in the optical substrates as well as in the dielectric coatings. A possible method for minimizing thermal noise is cooling to cryogenic temperature...

متن کامل

Modeling and optimization of precipitation hardening heat treatment factors of Al2024 alloy using a two-level full factorial design

In the current study, the sources of variation in the mean hardness value of heat treated aluminum 2024 samples were identified by using metallurgical study and design of experiment methodology (full factorial method). Hardness measurements and microstructural investigations of the samples were carried out using Brinell hardness test and optical microscopy, respectively. The effects of several ...

متن کامل

A Noise-Temperature Measurement System Using a Cryogenic Attenuator

Accurate and rapid noise-temperature measurements are critical to the modeling and development of high electron mobility transistor (HEMT) cryogenically cooled amplifiers. Four different techniques have been used in the laboratory to make noise-temperature measurements of cryogenically cooled amplifiers, and each of these is described below. Following this, the cryogenic pad method, the method ...

متن کامل

Quadrature Mach–Zehnder interferometer with application in optical coherence tomography

A novel quadrature interferometer based on Mach–Zehnder configuration and a 3 × 3 fibre coupler is presented. Measurements showing instantaneous extraction of both real and complex parts of the interferometric signal are described. The features of this quadrature interferometric platform are discussed with a focus on signal-to-noise ratio and optical power handling.

متن کامل

Exergy Optimization Applied to Linear Parabolic

A new method of optimization on linear parabolic solar collectors using exergy analysis is presented. A comprehensive mathematical modeling of thermal and optical performance is simulated and geometrical and thermodynamic parameters were assumed as optimization variables. By applying a derived expression for exergy efficiency, exergy losses were generated and the optimum design and operating co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016