A biomechanical comparison of 360° stabilizations for corpectomy and total spondylectomy: a cadaveric study in the thoracolumbar spine

نویسندگان

  • Jung-Hoon Kim
  • John M. Rhee
  • Yoshio Enyo
  • William C. Hutton
  • Sung-Soo Kim
چکیده

BACKGROUND To date, there has been no adequate biomechanical model that would allow a quantitative comparison in terms of stability/stiffness between a corpectomy with the posterior column preserved and a total spondylectomy with the posterior column sacrificed. The objective of this study was to perform a biomechanical comparison of 360° stabilizations for corpectomy and total spondylectomy, using the human thoracolumbar spine. METHODS Five human cadaveric thoracolumbar spines (T8-L2) were tested according to the following loading protocol: axial compression, flexion, extension, lateral bending to the right and left, and axial rotation to the right and left. This loading protocol was applied three times. Each specimen was tested intact, after corpectomy, and after total spondylectomy. The relative stiffness of each motion segment was determined for each test. RESULTS There was no significant difference in stiffness after reconstruction of total spondylectomy versus corpectomy in our thoracolumbar model. Our construct consisted of an anterior cage and four-level pedicle screw instrumentation (two above and two below) and provided similar stiffness in both models. Despite the additional bone resection in a total spondylectomy versus corpectomy, the constructs did not differ biomechanically. Additionally, there was no significant difference in stiffness between the intact specimen and either reconstruction model. CONCLUSIONS A classic corpectomy, which leaves the posterior column intact, is no better in terms of stability/stiffness than a total spondylectomy carried out using a shorter cage, followed by compression using posterior instrumentation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biomechanical study of thoracolumbar junction fixation devices with different diameter dual-rod systems.

OBJECT Advances in the design of a smaller-diameter rod system for use in the thoracolumbar region prompted the authors to undertake this biomechanical study of two different thoracolumbar implants. METHODS In vitro biomechanical testing was performed using human cadaveric spines. All specimens were loaded to a maximum moment of 5 Nm with 300-N axial preload in six modes of motion. Two types ...

متن کامل

Minimally invasive lateral retropleural thoracolumbar approach: cadaveric feasibility study and report of 4 clinical cases.

BACKGROUND Traditional anterior and posterior approaches to the thoracolumbar spine are associated with significant morbidity. In an effort to eliminate these drawbacks, minimally invasive retropleural approaches have been developed. OBJECTIVE To demonstrate the feasibility and clinical experience of a minimally invasive lateral retropleural approach to the thoracolumbar spine. METHODS Seve...

متن کامل

Two in vivo surgical approaches for lumbar corpectomy using allograft and a metallic implant: a controlled clinical and biomechanical study.

BACKGROUND CONTEXT Both bone graft and metallic implants have been used in combination with the necessary anterior rod or plate instrumentation to fill the voids left by vertebral body removal, with the ultimate goal of restoring stability. One type of device that has recently been introduced is an expandable titanium telescoping cage that is designed to be used as a strut implant to fill corpe...

متن کامل

Anterior Cervical Incision and Thoracotomy for Cervico-thoracic, Thoracic, and Thoracolumbar Spine Surgery: A Clinical Series

Introduction:Surgical treatment of diseases in cervicothoracic, thoracic and thoracolumbar regions can be a challenging issue. Cooperation of the thoracic surgeons and spine surgeons can improve the outcomes and decrease the complications of patients who underwent these approaches.Materials & Methods: The participants of this study consisted of seventeenpatients suffering from different types o...

متن کامل

Efficacy of Titanium Mesh Cages for Anterior Column Reconstruction after Thoracolumbar Corpectomy.

STUDY DESIGN This retrospective study was conducted to determine the safety and efficacy of titanium cage reconstruction and anterior plating after thoracolumbar corpectomy. PURPOSE To study the clinical and radiological outcome of anterior column reconstruction after thoracolumbar corpectomy. OVERVIEW OF LITERATURE Anterior column reconstruction aims to optimize neural decompression with a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015