Characterization of ordered-subsets expectation maximization with 3D post-reconstruction Gauss filtering and comparison with filtered backprojection in 99mTc SPECT.
نویسندگان
چکیده
PURPOSE To characterize ordered-subset expectation maximization algorithm with a fixed 3D Gauss post-reconstruction filtering (OSEM) in 99mTc SPECT as for noise, contrast and spatial resolution with varying number of subset and iteration and to compare OSEM with an optimized set of parameters, with filtered backprojection (FBP) with filter parameters typical of brain and myocardial SPECT, both with and without Chang's method of attenuation correction (AC). METHODS SPECT images of a Jaszczak phantom with cold rod inserts, hot and cold spheres and capillary line sources were acquired. Different background activity concentrations of the phantom were simulated as well as different lesion-to-background activity ratios. OSEM reconstructions were halted after 5, 10 and 15 iterations using 4, 8 and 16 subsets. RESULTS The effect of subset and iteration number over noise is additive: thus, it is possible to define an EM-equivalent iteration number that indicates the product between the subset and the iteration numbers. Noise increases linearly with increasing EM-equivalent iteration number. For each level of nominal contrast, the measured contrast after OSEM shows a little increase with increasing iteration number and saturates after 80 EM-equivalent iterations. The application of AC leads to diminished contrast values both in FBP and OSEM. The contrast of cold lesions after OSEM increases with increasing number of EM-equivalent iteration number: after 80 iterations the contrast values with OSEM overtake the ones obtained with FBP; contrast values diminished as background concentration raised. Resolution values did not change with increasing EM-equivalent iteration number and were higher than those obtained with FBP. CONCLUSION The major findings of the present work are the demonstration of additivity of subset and iteration in OSEM over noise, with the possibility of defining an EM equivalent iteration number, and the superiority of OSEM with respect to FBP in terms of spatial resolution.
منابع مشابه
Impact of reconstruction method on quantitative parameters of 99mTc-TRODAT-1 SPECT
Introduction: Quantitative evaluation is recommended to improve diagnostic ability and serial assessment of dopamine transporter (DAT) density scans. We decided to compare the ordered subsets expectation-maximization (OSEM) with filtered back-projection (FBP), and to investigate the impact of different iteration and cut-off frequencies on SBR values. Methods</stro...
متن کاملComparison of a noise-weighted filtered backprojection algorithm with the Standard MLEM algorithm for poisson noise.
Iterative maximum-likelihood expectation maximization and ordered-subset expectation maximization algorithms are excellent for image reconstruction and usually provide better images than filtered backprojection (FBP). Recently, an FBP algorithm able to incorporate noise weighting during reconstruction was developed. This paper compares the performance of the noise-weighted FBP algorithm and the...
متن کاملEffective Emission Tomography Image Reconstruction Algorithms for SPECT Data
Medical image reconstruction from projections is computationally intensive task that demands solutions for reducing the processing delay in clinical diagnosis applications. This paper analyzes reconstruction methods combined with preand post-filtering for Single Photon Emission Computed Tomography (SPECT) in terms of convergence speed and image quality. The evaluation is performed by means of a...
متن کاملImproving spatial resolution in SPECT with the combination of PSPMT based detector and iterative reconstruction algorithms.
This paper investigates the possibility of developing a SPECT system that combines the high spatial resolution of position sensitive photomultiplier tubes (PSPMTs) with the excellent performance of iterative reconstruction algorithms. A small field of view (FOV) camera based on a PSPMT and a pixelized scintillation crystal made of CsI(Tl) have been used for the acquisition of the projections. W...
متن کاملSingle Photon Imaging and Instrumentation
Abbreviations 2D, 3D 2-dimensional, 3-dimensional CZT cadmium zinc telluride EKG electric signal from the heart FBP filtered backprojection FOV field-of-view GE General Electric Ge(Li) germanium detector doped with lithium MLEM maximum likelihood expectation maximization NaI(Tl) sodium iodine doped with thallium NM nuclear medicine OSEM ordered subset expectation maximization PET positron emiss...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Annals of nuclear medicine
دوره 19 2 شماره
صفحات -
تاریخ انتشار 2005