A comparison of the International Standards Organisation reference method for the detection of coliforms and Escherichia coli in water with a defined substrate procedure.

نویسندگان

  • S I Niemela
  • J V Lee
  • C R Fricker
چکیده

AIMS This study investigated the use of the International Standards Organisation (ISO) procedure for the comparison of microbiological methods. Using this procedure the ISO reference procedure for the detection of coliforms and Escherichia coli in water was compared with a defined substrate method (ColilertTM). METHODS AND RESULTS A total of 20 laboratories from 13 European countries compared the use of Colilert/Quanti-TrayTM, a quantitative defined substrate test (DST) for the presence of coliforms and E. coli with the ISO reference procedure, which utilizes tergitol-TTC medium. Results of the study showed that DST detected significantly more coliforms and E. coli than did the reference procedure. In the case of E. coli the recoveries were also higher when using DST and the difference seen was statistically significant. The confirmation rate obtained when using the DST product suggested that no confirmation of wells positive for E. coli was necessary during routine use. CONCLUSIONS Colilert is a suitable alternative to the ISO reference procedure for the detection of coliforms and E. coli in water. The methods used during the comparison study indicated that confirmation of all colonies/positive wells led to the most accurate information and it is recommended that for future comparison studies this should become standard practice. Confirmation of a small proportion of colonies led to misleading conclusions and should be avoided when comparing microbiological methods. SIGNIFICANCE AND IMPACT OF STUDY It has been demonstrated that the ISO reference procedure fails to detect a significant proportion of coliforms and E. coli in drinking water. Colilert/QuantiTrayTM is a more suitable alternative.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Three Methods of Pour Plate (PP) ، Most Probable Number (MPN)and Membrane Filter (MF) for Detection of Escherichia coliin Well Water Samples in Tehran's Parks in 2010

Abstract Background and objectives: Water-born diseases are typically caused by pathogens transmitted by orofecal way. Because it is no practical and no economical and also it is time-consuming to find water-born pathogens in water reservoirs, the laboratory studies are performed on the basis of indicator microorganism. Escherichia coli is considered as the most important indicator bacterium fo...

متن کامل

ارزیابی توانایی کلستریدیوم پرفرنژنس در تعیین آلودگی مدفوعی آب در مقایسه با باکتری های شاخص

Introduction & Purpose Fecal coliforms and Escherichia coli have been conventionally used as indicators of microbial pollution of drinking water. The European Directive on drinking water quality has included Clostridium perfringens as one of the microbiological parameters to be determined in control of the water quality for human consumption. This study was carried out to evaluate the efficien...

متن کامل

National field evaluation of a defined substrate method for the simultaneous detection of total coliforms and Escherichia coli from drinking water: comparison with presence-absence techniques.

A defined substrate method was applied to drinking water to simultaneously enumerate total coliforms and total Escherichia coli directly from samples. After incubation at 35 degrees C for 24 h, the development of yellow in an initially colorless solution was specific for total coliforms; fluorescence at 366 nm in the same tube(s) or vessel demonstrated the presence of E. coli. No confirmatory o...

متن کامل

The Effect of Gamma (γ) Irradiation to inactivate Escherichia coli in Contaminated water

Several common approaches are used for disinfection of water in this section, but using the approaches (e.g. chlorination) are accompanied with hazardous by-products and also lead to notable changes in odor and flavor of water. Gamma irradiation as an emerging method has been encouraged currently by FAO/WHO for water, wastewater and food treatment. Coliform bacteria belong to common contaminant...

متن کامل

Comparison of ertapenem non-susceptibility with 2-mercaptopropionic acid phenotypic tests in predicting NDM-1 and IMP-1 production in clinical isolates of Escherichia coli

Background: A routine phenotypic test has not been recommended for detection of metallo-β-lactamases (MBLs) producing Enterobacteriaceae species such as Escherichia coli. The current study was conducted to compare the 2-Mercaptopropionic acid (2-MPA) phenotypic method and ertapenem non-susceptibility test with polymerase chain reaction in predicting the production of MBLs in clinical isolates o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied microbiology

دوره 95 6  شماره 

صفحات  -

تاریخ انتشار 2003