Flexion Gap Measured in 45 Degrees and 90 Degrees of Hip Flexion Positions during Total Knee Arthroplasty: Measurement by Navigation System

نویسندگان

  • Jin Kyu Lee
  • Kyu-Sung Chung
  • Bo-Hyun Kim
  • Choong Hyeok Choi
چکیده

PURPOSE To evaluate the influence of thigh weight in different hip flexion positions on the knee flexion gap in total knee arthroplasty (TKA). MATERIALS AND METHODS We evaluated 20 patients (25 knees) with osteoarthritis of the knee that underwent TKA using a navigation system from May 2010 to April 2011. After posterior cruciate ligament sacrificing, complete soft tissue balancing, and fixation of all components with cement, the flexion gaps were measured with the patello-femoral joint reduced. Medial and lateral flexion gaps were measured separately in both the 90°-90° and 45°-90° flexion positions of the hip-knee joints. RESULTS The medial and lateral flexion gaps in the 45°-90° flexion position of the hip-knee joints were 13.02±2.17 mm and 13.12±2.21 mm, respectively. The medial and lateral flexion gaps in the 90°-90° flexion position were 12.92±2.03 mm and 13.08±2.29 mm, respectively. The flexion gaps showed no significant (p>0.05) differences between the two different hip flexion positions. CONCLUSIONS Flexion gaps in TKA were not influenced by hip flexion positions (45° or 90° of flexion). Therefore, soft tissue balancing and polyethylene thickness should not be affected by hip flexion positions during TKA.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

VASTUS MEDIALIS OBLIQUE AND VASTUS LATERALISACTIVITIES RATIO ON SELECTED DEGREES OF RANGE OF MOTION IN OPEN AND CLOSED KINETIC CHAIN DURING ISOMETRIC CONTRACTION

Background: The purpose of this study was to investigate the ratio of Electromyography (EM G) activities of the vastus medialis obliqus (VMO) and vastus lateralis (VL) within seven angles of knee joint range of motion using isometric contraction in open kinetic chain (OK C) and closed kinetic chain (CKC). Methods: The dominant knees of 44 healthy female subjects (mean age: 24.84 with range...

متن کامل

Native Knee Laxities at 0°, 45°, and 90° of Flexion and Their Relationship to the Goal of the Gap-Balancing Alignment Method of Total Knee Arthroplasty.

BACKGROUND Gap-balancing is an alignment method for total knee arthroplasty with the goal of creating uniform tension in the periarticular soft-tissue restraints and equal laxities throughout the arc of flexion. However, there is little evidence that achieving equal laxities prevents either overly tight or overly loose soft-tissue restraints after total knee arthroplasty. Accordingly, the purpo...

متن کامل

Evaluation of soft-tissue balance during total knee arthroplasty.

PURPOSE To evaluate soft-tissue balance during versus after total knee arthroplasty (TKA). METHODS 18 men and 75 women aged 52 to 85 (mean, 68) years who had moderate-to-severe varus deformity underwent TKAs using the Scorpio non-restrictive geometry posterior-stabilised system (Stryker Howmedica Osteonics; Allendale, [NJ], USA). All surgeries were performed by a single surgeon using the medi...

متن کامل

The Effect of Sagittal Femoral Bowing on the Femoral Component Position in Total Knee Arthroplasty

Background: In the current study, we investigated that how sagittal femoral bowing can affect the sagittal alignment ofthe femoral component in total knee arthroplasty (TKA).Methods: There were 25 patients underwent TKA. Long leg radiography in lateral view was performed. The sagittalfemoral bowing (SFB) and component alignment in relation to the sagittal mechanical axis and distal anterior cor...

متن کامل

The intra-operative joint gap in cruciate-retaining compared with posterior-stabilised total knee replacement.

We have developed a new tensor for total knee replacements which is designed to assist with soft-tissue balancing throughout the full range of movement with a reduced patellofemoral joint. Using this tensor in 40 patients with osteoarthritis we compared the intra-operative joint gap in cruciate-retaining and posterior-stabilised total knee replacements at 0 degrees , 10 degrees , 45 degrees , 9...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 26  شماره 

صفحات  -

تاریخ انتشار 2014