The efficacy of three objective systems for identifying beef cuts that can be guaranteed tender.

نویسندگان

  • T L Wheeler
  • D Vote
  • J M Leheska
  • S D Shackelford
  • K E Belk
  • D M Wulf
  • B L Gwartney
  • M Koohmaraie
چکیده

The objective of this study was to determine the accuracy of three objective systems (prototype BeefCam, colorimeter, and slice shear force) for identifying guaranteed tender beef. In Phase I, 308 carcasses (105 Top Choice, 101 Low Choice, and 102 Select) from two commercial plants were tested. In Phase II, 400 carcasses (200 rolled USDA Select and 200 rolled USDA Choice) from one commercial plant were tested. The three systems were evaluated based on progressive certification of the longissimus as "tender" in 10% increments (the best 10, 20, 30%, etc., certified as "tender" by each technology; 100% certification would mean no sorting for tenderness). In Phase I, the error (percentage of carcasses certified as tender that had Warner-Bratzler shear force of > or = 5 kg at 14 d postmortem) for 100% certification using all carcasses was 14.1%. All certification levels up to 80% (slice shear force) and up to 70% (colorimeter) had less error (P < 0.05) than 100% certification. Errors in all levels of certification by prototype BeefCam (13.8 to 9.7%) were not different (P > 0.05) from 100% certification. In Phase I, the error for 100% certification for USDA Select carcasses was 30.7%. For Select carcasses, all slice shear force certification levels up to 60% (0 to 14.8%) had less error (P < 0.05) than 100% certification. For Select carcasses, errors in all levels of certification by colorimeter (20.0 to 29.6%) and by BeefCam (27.5 to 31.4%) were not different (P > 0.05) from 100% certification. In Phase II, the error for 100% certification for all carcasses was 9.3%. For all levels of slice shear force certification less than 90% (for all carcasses) or less than 80% (Select carcasses), errors in tenderness certification were less than (P < 0.05) for 100% certification. In Phase II, for all carcasses or Select carcasses, colorimeter and prototype BeefCam certifications did not significantly reduce errors (P > 0.05) compared to 100% certification. Thus, the direct measure of tenderness provided by slice shear force results in more accurate identification of "tender" beef carcasses than either of the indirect technologies, prototype BeefCam, or colorimeter, particularly for USDA Select carcasses. As tested in this study, slice shear force, but not the prototype BeefCam or colorimeter systems, accurately identified "tender" beef.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Adding Enzymes to Improve Beef Tenderness

Importance of Beef Tenderness Beef palatability is affected by many factors and tenderness is cited as one of the most important. Consumers are willing to pay a premium for a guaranteed tender product with the potential to increase the value of the middle meats over $60 per carcass (Miller et al., 2001). Consequently, the meat industry is in a continual search for methods to improve the tendern...

متن کامل

Consumer thresholds for establishing the value of beef tenderness.

In the present study, a national consumer evaluation was conducted for beef tenderness on USDA Select strip loin steaks of known Warner-Bratzler shear (WBS) force values, ranging from tough (> 5.7 kg) to tender (< 3.0 kg), and to assess the monetary value that consumers place on tenderness by determining the average price a consumer would pay for a steak in three tenderness categories. Three su...

متن کامل

Effect of age and cut on cooking loss, juiciness and flavour of South African beef.

The juiciness and flavour characteristics of 15 aged primal beef cuts of electrically stimulated carcasses, from three different age groups, were assessed (n=61). Cooking losses were determined and proximate analyses (moisture, fat, nitrogen and ash) were performed. Tender cuts were cooked by a dry heat method, and less tender cuts were cooked by moist heat methods. A trained panel (n=10) evalu...

متن کامل

National beef tenderness survey.

To determine the average tenderness and sensory ratings of beef subprimal cuts sold in retail cases across the United States, retail cuts were purchased through typical retail outlets in 14 metropolitan cities and transported to Texas A&M University for sensory and Warner-Bratzler shear analysis. The overall mean shear force for all cuts was 3.65 kg, and the mean shear force values for chuck, r...

متن کامل

NON-FRAGILE GUARANTEED COST CONTROL OF T-S FUZZY TIME-VARYING DELAY SYSTEMS WITH LOCAL BILINEAR MODELS

This paper focuses on the non-fragile guaranteed cost control problem for a class of T-S fuzzy time-varying delay systems with local bilinear models. The objective is to design a non-fragile guaranteed cost state feedback controller via the parallel distributed compensation (PDC) approach such that the closed-loop system is delay-dependent asymptotically stable and the closed-loop performance i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of animal science

دوره 80 12  شماره 

صفحات  -

تاریخ انتشار 2002