Distributed Generation and Reclosing Coordination

نویسنده

  • Lauri Kumpulainen
چکیده

Distribution networks have traditionally been designed for unidirectional power flow. Large scale implementation of distributed generation (DG) means that this fundamental assumption is not true any more. This causes several challenges to network design and operation. One of the most critical affected areas is system protection. The impact of DG on protection has been examined in several research papers during the last years. The most challenging issue seems to be anti-islanding protection, especially when automatic reclosing is applied. In this paper, the effect of DG on automatic reclosing is studied. After a short literature review, the method and results of simulation studies are presented. The simulations verify the existence of the problems. Protection requirements and possible solutions are discussed. Because of speed and reliability requirements, telecommunication based protection seems to be the most suitable solution, when the share of DG becomes significant. IMPORTANCE OF AUTOMATIC RECLOSING In medium voltage overhead networks all over the world automatic reclosing is widely used and a very effective method of fault clearing. According to [1], 70-95% of the faults are temporary. Figure 1 illustrates the importance of automatic reclosing according to a Finnish study [2]. Figure 1. Share of different faults and fault clearing by automatic reclosing in Finnish overhead networks [2].

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Protection Coordination Issues Distributed Generation Systems

With this distributed generation (DG) in distribution systems, its function generally tends to be changed. These effects leads to effects on distribution systems protection. One way to reduce the effects of distributed generation protection system of distribution systems is re-coordination of protective devices. To prevent the high cost, system configuration should be modified to reduce the DG ...

متن کامل

Fault Diagnosis in Distribution Networks with Distributed Generation

The penetration of distributed generation (DG) in distribution power system would affect the traditional fault current level and characteristics. Consequently, the traditional protection arrangements developed in distribution utilities are difficult in coordination. Also, the reclosing scheme would be affected. With the rapid developments in distribution system automation and communication tech...

متن کامل

Protection Coordination Based on Multi-agent for Distribution Power System with Distribution Generation Units

-The penetration of DGs would drastically affect the traditional distribution power system fault current level and the characteristics of fault currents, consequently, the traditional protection arrangements developed in radial systems are difficult in coordination, and also the reclosing scheme would be affected. With the rapid developments in distribution system automation and communication t...

متن کامل

Optimal Distributed Generation Planning in Radial Distribution Networks Considering Protection Coordination Limits

Distributed generation (DG) has been widely used in distribution network to reduce the energy losses, improve voltage profile and system reliability, etc.  The location and capacity of DG units can influence on probability of protection mal-operation in distribution networks. In this paper, a novel model for DG planning is proposed to find the optimum DG location and sizing in radial distr...

متن کامل

Development of a Leader-End Reclosing Algorithm Considering Turbine-Generator Shaft Torque

High-speed auto-reclosing is used in power system protection schemes to ensure the stability and reliability of the transmission system; leader-follower auto-reclosing is one scheme type that is widely used. However, when a leader-follower reclosing scheme responds to a permanent fault that affects a transmission line in the proximity of a generation plant, the reclosing directly impacts the tu...