Morphological Characterization of the Polyflux 210H Hemodialysis Filter Pores

نویسندگان

  • A. Hedayat
  • J. Szpunar
  • N. A. P. Kiran Kumar
  • R. Peace
  • H. Elmoselhi
  • A. Shoker
چکیده

Background. Morphological characterization of hemodialysis membranes is necessary to improve pore design. Aim. To delineate membrane pore structure of a high flux filter, Polyflux 210H. Methods. We used a Joel JSM-6010LV scanning electron microscope (SEM) and a SU6600 Hitachi field emission scanning electron microscope (FESEM) to characterize the pore and fiber morphology. The maximal diameters of selected uremic toxins were calculated using the macromolecular modeling Crystallographic Object-Oriented Toolkit (COOT) software. Results. The mean pore densities on the outermost and innermost surfaces of the membrane were 36.81% and 5.45%, respectively. The membrane exhibited a tortuous structure with poor connection between the inner and outer pores. The aperture's width in the inner surface ranged between 34 and 45 nm, which is 8.76-11.60 times larger than the estimated maximum diameter of β2-microglobulin (3.88 nm). Conclusion. The results suggest that the diameter size of inner pore apertures is not a limiting factor to middle molecules clearance, the extremely diminished density is. Increasing inner pore density and improving channel structure are strategies to improve clearance of middle molecules.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Study of Dialyzer Membrane (Polyflux 210H) and Effects of Different Parameters on Dialysis Performance

Problems frequently encountered in kidney malfunction include abnormal fluid levels in the body, increased acid levels, abnormal levels of Urea, Glucose, Endothelin, β2-Microglobulin and Complement Factor D. Parameters characterizing the structure of dialyzers are very important because they decide overall clearance of toxin molecules and at the same time should allow retaining useful molecules...

متن کامل

Enhancement of Toxic Substances Clearance from Blood Equvalent Solution and Human Whole Blood through High Flux Dialyzer by 1 MHz Ultrasound

Background: Hemodialysis is a process of removing waste and excess fluid from blood when kidneys cannot function efficiently. It often involves diverting blood to the filter of the dialysis machin to be cleared of toxic substances. Fouling of pores in dialysis membrane caused by adhesion of plasma protein and other toxins will reduce the efficacy of the filtre.Objective: In This study, the infl...

متن کامل

Determination of vancomycin and gentamicin clearance in an in vitro, closed loop dialysis system

BACKGROUND The purpose of this study was to evaluate the feasibility of utilizing an in-vitro, closed loop hemodialysis system as a method to assess drug clearance. Secondarily, this study tested the influence of variables (blood flow rate, dialysate flow rate, and type of filter) in the hemodialysis procedure on the clearance of vancomycin and gentamicin. METHODS An in-vitro, closed loop hem...

متن کامل

نقش انواع فیلتر در میزان هیپوکسمی بیماران همودیالیزی

Introduction: One of the main complications of hemodialysis in patients with chronic renal failure is hypoxemia which is related to several factors including the type of filter. The aim of this study was to evaluate the hypoxemia levels in patients undergoing hemodialysis with focus on the type of filter. Methods: In a crossover clinical trial, 29 patients from emodialysis ward of Fatemieh hos...

متن کامل

Fabrication of Copper and Iron Nano/Micro Structures on Semiconducting Substrate and Their Electrical Characterization

In this paper, we have studied the electrical properties of the randomly distributed metallic (Co and Fe) nano/ micro wires on Silicon substrate. Deposition was carried out potentiostatically into the pores of the track-etch polycarbonate membrane spin coated onto the Si substrate. Spin coated films were irradiated with 150MeV Ni (+11) ions at a fluence of 8E7 ions/cm2, followed by UV irradiati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2012  شماره 

صفحات  -

تاریخ انتشار 2012