Comparison of brain MR images at 1.5T using BLADE and rectilinear techniques for patients who move during data acquisition.
نویسندگان
چکیده
BACKGROUND AND PURPOSE MR imaging of moving patients can be challenging and motion correction techniques have been proposed though some have associated new artifacts. The objective of this study was to semiquantitatively compare brain MR images of moving patients obtained at 1.5T by using partially radial and rectilinear acquisition techniques. MATERIALS AND METHODS FLAIR, T2-, T1-, and contrast-enhanced T1-weighted image sets of 25 patients (14-94 years) obtained by using BLADE (like PROPELLER, a partially radial acquisition) and rectilinear techniques in the same imaging session were compared by 2 neuroradiologists in terms of extent of the motion artifact, image quality, and lesion visibility. ICC between opinions of the evaluators was calculated. RESULTS Of the total of 70 image sets, the motion artifact was small in the partially radial images in 43 and in the rectilinear images in 13, and the opinions of the evaluators were discordant in the remaining 14 sets (ICC = 0.63, P < .05). The quality of partially radial images was higher for 36 sets versus 9 rectilinear sets, with disagreement between the 2 evaluators in the remaining 25 (ICC = 0.15, P < .05). Pathologic lesions were better characterized on 37 sets of partially radial images versus 13 sets of rectilinear images, and opinions of the evaluators differed in 20 sets (ICC = 0.90, P < .05). The neuroradiologists deemed 4 sets of rectilinear images nondiagnostic compared with only 1 set of radial images. CONCLUSIONS The data demonstrate that our application of BLADE sequences reduces the extent of motion artifacts in brain images of moving patients, improving image quality and lesion characterization.
منابع مشابه
Comparison of state-of-the-art atlas-based bone segmentation approaches from brain MR images for MR-only radiation planning and PET/MR attenuation correction
Introduction: Magnetic Resonance (MR) imaging has emerged as a valuable tool in radiation treatment (RT) planning as well as Positron Emission Tomography (PET) imaging owing to its superior soft-tissue contrast. Due to the fact that there is no direct transformation from voxel intensity in MR images into electron density, itchr('39')s crucial to generate a pseudo-CT (Computed Tomography) image ...
متن کاملT2-weighted Liver Mri at 3t Using a Blade Technique: Comparison with a Standard Rectilinear T2-weighted Sequence for Image Quality and Lesion Detection
Introduction: The quality of T2-weighted images (T2WI) of the liver in the clinical setting is often degraded by ghosting artifact from various sources of motion. This artifact can obscure the margins of the liver, intra-hepatic vessels, and focal liver lesions, lowering diagnostic utility. One study has noted that such motion within the liver is more severe at 3T compared with at 1.5T [1]. Fur...
متن کاملComparison the Accuracy of Fetal Brain Extraction from T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (HASTE) MR Image with T2-True Fast Imaging with Steady State Free Precession (TRUFI) MR Image by Level Set Algorithm
Background Access to appropriate images of fetal brain can greatly assist to diagnose of probable abnormalities. The aim of this study was to compare the suitability of T2-True Fast Imaging with Steady State Free Precession (T2-TRUFI), and T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (T2- HASTE( magnetic resonance imaging (MRI) to extract the fetal brain using the level set algorithm...
متن کاملCompensation of brain shift during surgery using non-rigid registration of MR and ultrasound images
Background: Surgery and accurate removal of the brain tumor in the operating room and after opening the scalp is one of the major challenges for neurosurgeons due to the removal of skull pressure and displacement and deformation of the brain tissue. This displacement of the brain changes the location of the tumor relative to the MR image taken preoperatively. Methods: This study, which is done...
متن کاملDiagnostic Relevant Reduction of Motion Artifacts in the Posterior Fossa by syngo BLADE Imaging
Although movement and pulsation artifacts are a frequent problem in daily routine [1–4] especially in the diagnostics of pediatric patients, only few articles on this topic can be found in the literature. According to our experience mainly MR images of the posterior fossa, the cerebellum and the brain stem, may be significantly impaired by artifacts from pulsatile flow of blood or cerebrospinal...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 33 1 شماره
صفحات -
تاریخ انتشار 2012