Diffusion coefficient measurement using a temperature-controlled fluid for quality control in multicenter studies.

نویسندگان

  • Thomas L Chenevert
  • Craig J Galbán
  • Marko K Ivancevic
  • Susan E Rohrer
  • Frank J Londy
  • Thomas C Kwee
  • Charles R Meyer
  • Timothy D Johnson
  • Alnawaz Rehemtulla
  • Brian D Ross
چکیده

PURPOSE To present the use of a quality control ice-water phantom for diffusion-weighted magnetic resonance imaging (DW-MRI). DW-MRI has emerged as an important cancer imaging biomarker candidate for diagnosis and early treatment response assessment. Validating imaging biomarkers through multicenter trials requires calibration and performance testing across sites. MATERIALS AND METHODS The phantom consisted of a center tube filled with distilled water surrounded by ice water. Following preparation of the phantom, ≈30 minutes was allowed to reach thermal equilibrium. DW-MRI data were collected at seven institutions, 20 MRI scanners from three vendors, and two field strengths (1.5 and 3T). The phantom was also scanned on a single system on 16 different days over a 25-day period. All data were transferred to a central processing site at the University of Michigan for analysis. RESULTS Results revealed that the variation of measured apparent diffusion coefficient (ADC) values between all systems tested was ±5%, indicating excellent agreement between systems. Reproducibility of a single system over a 25-day period was also found to be within ±5% ADC values. Overall, the use of an ice-water phantom for assessment of ADC was found to be a reasonable candidate for use in multicenter trials. CONCLUSION The ice-water phantom described here is a practical and universal approach to validate the accuracy of ADC measurements with ever changing MRI sequence and hardware design and can be readily implemented in multicenter clinical trial designs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Estimation of Binary Infinite Dilute Diffusion Coefficient Using Artificial Neural Network

In this study, the use of the three-layer feed forward neural network has been investigated for estimating of infinite dilute diffusion coefficient ( D12 ) of supercritical fluid (SCF), liquid and gas binary systems. Infinite dilute diffusion coefficient was spotted as a function of critical temperature, critical pressure, critical volume, normal boiling point, molecular volume in normal boilin...

متن کامل

Supercritical Fluid Extraction of β-Carotene from Crude Palm Oil Using CO2 in a Bubbler Extractor: Mass Transfer Study

In this study, the diffusivity and volumetric mass transfer coefficients for the extraction of β-carotene from crude palm oil using CO2 solvent in supercritical fluid were determined in the pressure range of 7.5-17.5 MPa and temperature range of 80-120 ºC. For this purpose, a statistical method was applied in order to minimize the number of experiments required. The volumetric ma...

متن کامل

Diffusion measurement in ferrous infused gel dosimeters

Background: The compositions of Ferrous sulphate, Agarose and Xylenol orange dye (FAX) and Ferrous sulphate, Gelatin and Xylenol orange dye (FGX) in solution of distilled water and sulphuric acid are two tissue-equivalent gel dosimeters. Ionizing radiation causes oxidation of Fe2+ ion to Fe3+ ions which diffuse through the gel matrix and blur the image of absorbed dose over a period of hours af...

متن کامل

Multi-system repeatability and reproducibility of apparent diffusion coefficient measurement using an ice-water phantom.

PURPOSE To determine quantitative quality control procedures to evaluate technical variability in multi-center measurements of the diffusion coefficient of water as a prerequisite to use of the biomarker apparent diffusion coefficient (ADC) in multi-center clinical trials. MATERIALS AND METHODS A uniform data acquisition protocol was developed and shared with 18 participating test sites along...

متن کامل

Dispersion Coefficients of Supercritical Fluid in Fixed Beds

The axial dispersion coefficient of hexachlorobenzene in supercritical carbon dioxide is investigated in a fixed-bed packed with glass beads. The on-line chromatographic pulse-response experiment is used in order to study the dynamics of a packed column under supercritical conditions. The radial dispersion is assumed negligible because of the packed column geometry. To estimate the axial disper...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of magnetic resonance imaging : JMRI

دوره 34 4  شماره 

صفحات  -

تاریخ انتشار 2011