Measurement precision of the anaerobic threshold by means of a portable calorimeter.
نویسندگان
چکیده
BACKGROUND Many methods are used for determining the Anaerobic Threshold (AT) by means of sophisticated ergospirometer. OBJECTIVE To test the AT variation, detected by mathematical models and visual inspection, when low cost ergospirometer is used and intended for clinical application. METHODS Seventy nine apparently healthy subjects were volunteers in this study; from these, 57 men. The VO₂(max) and the ventilatory threshold were determined by indirect, open-circuit calorimetry. The electro-enzymatic method was used for analyzing the lactacidemia and direct determination of the Lactate Threshold (LT). The AT was determined by two mathematical methods (MM(RSS) and MM(slope)), based on the gases exchange, and by the log-log visual method, for determining the LT. Two independent investigators determined the AT through visual inspection of three graphs, considering two methods (AT₋(a)= V-slope, EqV; and AT₋(b) = V-slope, EqV and ExCO₂). The data were analyzed by means of parametric statistics for determining the differences between AT₋(a) versus ExCO₂, MM(RSS) and MM(slope); AT-b versus MM(RSS) and MM(slope); and LT versus AT₋(a), AT₋(b), MM(RSS) and MM(slope). RESULTS The MM(slope) was the only method that presented a significant difference between the AT₋(a) and AT₋(b) (p=0.001), with CV% >15. LT versus MM(slope) did not present significant difference (p=0.274), however, it was observed a high CV (24%). CONCLUSION It was concluded that with the low cost equipment, the MM(RSS) and AT₋(a) methods can be used for determining the TAn. The MM(slope) method did not present satisfactory precision to be employed with this equipment.
منابع مشابه
The Effect of Quadriceps Kinesio Taping on the Anaerobic Muscle Power and Anaerobic Threshold of ََActive Male Students
Introdution: The Purpose of this study examined the effect of Kinesio taping the quadriceps femurs muscle of active students on anaerobic muscle power (AMP) and the anaerobic threshold (AT) to analyze the functional value of taping on athletic performance capacity. Methods: Twenty eight male healthy students with a mean age of 22.02±2.2 years were enrolled in this study voluntarily and randoml...
متن کاملvALIdITY OF THE CONCONI TEST IN ESTImATION OF ANAErOBIC THrESHOLd durING CYCLING
This study was designed to assess the validity of Conconi’s method, by means of heart rate and lactate threshold measurements to predict anaerobic threshold. The results presented in this paper, clearly demonstrate significant difference between anaerobic threshold values obtained by means of Conconi’s test (Conconi’s threshold) and anaerobic threshold values obtained by direct lactate blood co...
متن کاملEfficiency of Canopy Cover Measurement of Artemisia sieberi Stands by Two Sampling Methods in Different Lengths (Case study: Steppe Vegetation of Baft Region, Iran)
This research has been conducted to establish a wheel-point device and evaluate its efficiency (precision, accuracy and time) with respect to the estimation of canopy percent in a pilot Artemisia stand in Khabr region of Baft, Kerman province, Iran in 2015. Several transects with different lengths (30, 60, 90, 120, 150 and 180 m) were established using the randomized sampling block with 5 repli...
متن کاملThe Effect of Physiological Load during Matches on the Quality of Refereeing in Handball Referees
Background. Referees are an integral part of every handball match which is considered a high-intensity activity and they need to follow the action as close as possible to avoid mistakes in their decisions. Objectives. This research aimed to determine the physiological loads of referees during handball matches and whether a higher physiological load during the match has a significant effect on ...
متن کاملNon-ionizing electromagnetic waves measurement and monitoring Systems
In this paper, portable and online monitoring systems for non-ionizing EMF measurement, as well as some measurement results in Tehran are discussed. First of all, standards and recommendations related to EMF monitoring, measurement and exposure such as ISIRI No.8567, ICNIRP guideline and ITU-K.83 are reviewed. Then, technical facts and operation of portable device and monitoring station are int...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Arquivos brasileiros de cardiologia
دوره 95 3 شماره
صفحات -
تاریخ انتشار 2010