Analysis of polysorbate 80 and its related compounds by RP-HPLC with ELSD and MS detection.

نویسندگان

  • R Zhang
  • Y Wang
  • L Tan
  • H Y Zhang
  • M Yang
چکیده

The chemical composition of polysorbate 80 strongly influences the physicochemical properties and performance of many products. Consequently, a reliable characterization of polysorbate 80 is crucial for many applications. However, the exact composition of these chemical mixtures cannot be determined by colorimetry, hydrolysis, size-exclusion chromatography, nuclear magnetic resonance or mass spectrometry (MS). Meanwhile, due to the strong retention of higher esters on the reversed-phase (RP) column, the published high-performance liquid chromatography (HPLC) methods suffered from inadequate elution. In the present paper, an HPLC-evaporative light scattering detection (ELSD) and an HPLC-electrospray ionization (ESI)-MS method were developed and validated for the separation and identification of the chemical composition of polysorbate 80. A full separation of the entire composition was achieved in 45 min. In the HPLC-ESI-MS spectra, each class of the compound in polysorbate 80 was directly confirmed and identified by [M + NH(4)](+) and [M + 2NH(4)](2+) ions. The number of polyoxyethylene groups and their distribution within the molecule were determined, in addition to the dehydration and esterification degree of sorbitol. Analysis showed that polysorbate 80 contained different proportions of components (polyoxyethylene sorbitan, polyoxyethylene isosorbide, polyoxyethylene sorbitan monooleate-dioesters-trioleates-tetraoleates and polyoxyethylene isosorbide monoester-dioesters). It was concluded that HPLC-ESI-MS is a useful tool for establishing the compositional profile of polysorbate 80.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

HPlC Analysis of Phospholipids by Evaporative laser light-Scattering Detection

oDays High-performance liquid chromatography (HPLC) for analysis of phospholipids has traditionally employed ultraviolet detection of the eluted compounds. The evaporative laser light-scattering detector (ELSD) offers new opportunities for quantitative analysis of lipids. Phospholipids were isolated from crude and degummed oils prepared from soyheans subjected to storage at high moisture conten...

متن کامل

Development of an RP-HPLC-UV method for simultaneous detection of nimodipine and its metabolite in cerebrospinal fluid of rat

A rapid, simple and reproducible HPLC method was developed and validated for the analysis of nimodipine (NM) and/or its metabolite, oxidized nimodipine (OX–NM) in rat cerebrospinal fluid (CSF) and artificial CSF. The NM and OX–NM were eluted in less than 10 min with no interferences from the endogenous CSF peaks. Analysis was carried out on a Eurospher Performance (RP-C18, 250 × 4.6 mm) column ...

متن کامل

Development of an RP-HPLC-UV method for simultaneous detection of nimodipine and its metabolite in cerebrospinal fluid of rat

A rapid, simple and reproducible HPLC method was developed and validated for the analysis of nimodipine (NM) and/or its metabolite, oxidized nimodipine (OX–NM) in rat cerebrospinal fluid (CSF) and artificial CSF. The NM and OX–NM were eluted in less than 10 min with no interferences from the endogenous CSF peaks. Analysis was carried out on a Eurospher Performance (RP-C18, 250 × 4.6 mm) column ...

متن کامل

Determination of vertilmicin sulfate and its related substances by HPLC-ELSD and HPLC-MS2.

A new and simple high-performance liquid chromatography (HPLC)-evaporative light scattering detection (ELSD) method for the determination of vertilmicin sulfate and its related substances is developed. The column is an Agilent SB-C(18) (250 x 4.6 mm, 5 microm). The mobile phase is 0.05 mol/L trifluoroacetic acid-methanol (85:15). Good separation of vertilmicin from the main related substances i...

متن کامل

Rapid Analysis of Glibenclamide Using an Environmentally Benign Stability-Indicating RP-HPLC Method

An environmentally benign RP-HPLC approach for rapid analysis of glibenclamide in pure form, developed nanoemulsion and commercial tablets was developed and validated in present investigation. The green chromatographic identification was performed on Lichrosphere 250 X 4.0 mm RP C8 column having a 5µm packing as a stationary phase using a combination of ethanol: methanol (50:50 % v/v) as a mobi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of chromatographic science

دوره 50 7  شماره 

صفحات  -

تاریخ انتشار 2012