Unusual pacemaker lead placement in an unsuspecting heart.
نویسندگان
چکیده
During the implantation process, the pacemaker leads advanced easily into the atrium and ventricle from the left subclavian vein. On fl uoroscopy, the locations of the leads in the atrium and ventricle appeared atypical (Fig. 1). An intraoperative transthoracic echocardiography was then performed, showing the atrial lead into the left atrium (Fig. 2). The pacemaker leads were then repositioned into the right heart chambers, but the procedure was quite diffi cult because the leads preferentially entered into the left heart chambers.
منابع مشابه
An Unusual Cause of Transient Ischemic Attack in a Patient with Pacemaker
Pacemaker lead malposition in various locations has been described in the literature. Lead malposition in left ventricle is a rare and an underdiagnosed complication. We present a 77-year-old man with history of atrial fibrillation and pacemaker placement who was admitted for transient ischemic attack. He was on aspirin, beta blocker, and warfarin with subtherapeutic international normalized ra...
متن کاملگزارش یک مورد سندرم لوپوس نوزادی
Neonatal lupus syndrome is a rare disease. The manifestations of this disease in neonatal period include congenital heart block, cutaneous leasions, liver disease, thrombocytopenia, Neutropenia, pulmonary and nurologic derangements. Most of the clinical manifestations ofter disappear spontaneously. Although congenital heart block is usually permanent, and often require pacemakers. Congenital he...
متن کاملA Rare Cause of Cardiac Tamponade: Left Ventricular Pacemaker Malposition
The malpositioning of a pacemaker lead is an uncommon and under-reported complication of pacemaker/Automated Implantable Cardioverter-Defibrillator (AICD) placement. It can be associated with complications such as pericardial effusions and tamponade. We describe a case of an elderly woman who developed cardiac tamponade after inadvertent placement of a permanent pacing lead in the left ventricl...
متن کاملA Novel Way Of Repair Of Insulation Breaks During Pacemaker Generator Replacement
Minor abrasions can occur while mobilising old lead during pacemaker generator replacement necesittating placement of additional lead adding to the financial burden and junk in heart. We describe a novel way of repair of old pacemaker lead preventing additional lead placement.
متن کاملTrans-Fontan baffle placement of an endocardial systemic ventricular pacing lead
Introduction Patients with single-ventricle physiology palliated to a Fontan can be at risk for high-grade atrioventricular block, necessitating permanent pacemaker placement. Historically, epicardial leads have been used for these patients given the concern for clot formation within the Fontan pathway or systemic ventricle. However, epicardial pacing systems are fraught with issues, including ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Annals of the Academy of Medicine, Singapore
دوره 39 7 شماره
صفحات -
تاریخ انتشار 2010