High Resolution Cat Imaging of Fractures in Consolidated Materials

نویسنده

  • A. A. Keller
چکیده

High resolution measurements of fracture aperture of granite and sandstone rocks were performed using CAT scanner. The aperture distribution was statistically characterized for future experimental and numerical studies on single and multiphase flow and transport. The fracture aperture can be measured in-situ and nondestructively with CAT-scanning. The minimum pixel size is 0.27 x 0.27 mm, but fractures as small as 35 μm can be accurately measured, using a calibration standard for the variation in CT number due to the “missing rock mass” in a given pixel. A calibration standard for each rock type yields distinctly different calibration slopes, about 17% greater for granite compared to sandstone, indicating that each rock type should be analyzed against its own calibration standard. The aperture distribution is rather heterogeneous and is best described by a lognormal function, corroborated by comparing the theoretical to actual ratio of hydraulic to mechanical apertures. Mechanical roughness of the fractures ranged from 0.17 to 1.5. The variability in fracture aperture displayed only short range structure, with correlation lengths of 0.8 mm to 7 mm, which is at most one-tenth of the minimum dimension (width) of the fracture plane. Potential flow channels can be deduced from the fracture aperture distribution.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Structural and fracture analysis using EMI and FMI image Log in the carbonate Asmari reservoir (Oligo-Miocene), SW Iran

Assessment of the reservoir structure and determination of theinsitu stress direction arenecessary in oil production optimization andfield development. Today, the application of reservoir software and Image logsplay a central role in resolving this problem. Electricand ultrasonic imaging tools record vast amounts of high-resolution data within the borehole wall. This enables the geoscientists t...

متن کامل

Diagnostic Accuracy of Different Resolutions of Cone Beam Computed Tomography Imaging System for Detection of Vertical Root Fractures In Presence of Casting Posts

  Objective: The diagnosis of vertical root fracture (VRF) in endodontically treated teeth is a clinical challenge due to lack of specific clinical and radiographic signs. Although radiographic evaluation such as CBCT is helpful, intracanal posts can produce artifacts and may impair the quality of CBCT scans. This study aimed to compare the diagnostic accuracy of different resolutions of CBCT i...

متن کامل

Systematic fractures analysis using image logs and complementary methods in the Marun Oilfield, SW Iran

Fractures are considered as one of the important structures in fractured reservoirs due to their effect on fluid currents and reservoirparameters such as porosity and permeability. Fracture parameters can only be directly calculated with core and image logs. Cores haveserious limitations, so image logs are the best method. The aim of this study is the systematic fractures analysis of the Asmari...

متن کامل

Robust Fuzzy Content Based Regularization Technique in Super Resolution Imaging

Super-resolution (SR) aims to overcome the ill-posed conditions of image acquisition. SR facilitates scene recognition from low-resolution image(s). Generally assumes that high and low resolution images share similar intrinsic geometries. Various approaches have tried to aggregate the informative details of multiple low-resolution images into a high-resolution one. In this paper, we present a n...

متن کامل

Recent Advances in PET-MR Hybrid contrast agent

Introduction: All of the Imaging modalities have advantages and disadvantages alone. So if we want to have the best and perfect image, combining these modalities produces something we desired. PET-MR images consist of morphologic and metabolic data. MRI and PET provide high spatial and contrast resolution and high sensitivity and molecular information respectively. Hybrid PET-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1997