Advances in Single-Particle Electron Cryomicroscopy Structure Determination applied to Sub-tomogram Averaging
نویسندگان
چکیده
Recent innovations in specimen preparation, data collection, and image processing have led to improved structure determination using single-particle electron cryomicroscopy (cryo-EM). Here we explore some of these advances to improve structures determined using electron cryotomography (cryo-ET) and sub-tomogram averaging. We implement a new three-dimensional model for the contrast transfer function, and use this in a regularized likelihood optimization algorithm as implemented in the RELION program. Using direct electron detector data, we apply both single-particle analysis and sub-tomogram averaging to analyze radiation-induced movements of the specimen. As in single-particle cryo-EM, we find that significant sample movements occur during tomographic data acquisition, and that these movements are substantially reduced through the use of ultrastable gold substrates. We obtain a sub-nanometer resolution structure of the hepatitis B capsid, and show that reducing radiation-induced specimen movement may be central to attempts at further improving tomogram quality and resolution.
منابع مشابه
An approach for de novo structure determination of dynamic molecular assemblies by electron cryomicroscopy.
Single-particle electron cryomicroscopy is a powerful method for three-dimensional (3D) structure determination of macromolecular assemblies. Here we address the challenge of determining a 3D structure in the absence of reference models. The 3D structures are determined by alignment and weighted averaging of densities obtained by native cryo random conical tilt (RCT) reconstructions including c...
متن کاملProblems in obtaining perfect images by single-particle electron cryomicroscopy of biological structures in amorphous ice.
Theoretical considerations together with simulations of single-particle electron cryomicroscopy images of biological assemblies in ice demonstrate that atomic structures should be obtainable from images of a few thousand asymmetric units, provided the molecular weight of the whole assembly being studied is greater than the minimum needed for accurate position and orientation determination. Howe...
متن کاملOptimal determination of particle orientation, absolute hand, and contrast loss in single-particle electron cryomicroscopy.
A computational procedure is described for assigning the absolute hand of the structure of a protein or assembly determined by single-particle electron microscopy. The procedure requires a pair of micrographs of the same particle field recorded at two tilt angles of a single tilt-axis specimen holder together with the three-dimensional map whose hand is being determined. For orientations determ...
متن کاملTemplate Matching, Alignment and Averaging of Sub-Tomograms in Electron Cryo-Tomography Reconstructions using Jsubtomo
Electron cryo-tomography has emerged as a widely used method for imaging different biological specimens and elucidating their three-dimensional structures. Suitable specimens range from macromolecular complexes, filamentous structures, coated vesicles and pleomorphic membrane viruses to procaryotic cells and thin areas eukaryotic cells. After sample preparation for electron cryo-microscopy, a t...
متن کاملNear-atomic resolution using electron cryomicroscopy and single-particle reconstruction.
Electron cryomicroscopy (cryo-EM) yields images of macromolecular assemblies and their components, from which 3D structures can be determined, by using an image processing method commonly known as "single-particle reconstruction." During the past two decades, this technique has become an important tool for 3D structure determination, but it generally has not been possible to determine atomic mo...
متن کامل