Comparison of Air Impaction and Electrostatic Dust Collector Sampling Methods to Assess Airborne Fungal Contamination in Public Buildings.

نویسندگان

  • Anne-Cécile Normand
  • Stéphane Ranque
  • Carole Cassagne
  • Jean Gaudart
  • Kankoé Sallah
  • Denis-André Charpin
  • Renaud Piarroux
چکیده

Many ailments can be linked to exposure to indoor airborne fungus. However, obtaining a precise measurement of airborne fungal levels is complicated partly due to indoor air fluctuations and non-standardized techniques. Electrostatic dust collector (EDC) sampling devices have been used to measure a wide range of airborne analytes, including endotoxins, allergens, β-glucans, and microbial DNA in various indoor environments. In contrast, viable mold contamination has only been assessed in highly contaminated environments such as farms and archive buildings. This study aimed to assess the use of EDCs, compared with repeated air-impactor measurements, to assess airborne viable fungal flora in moderately contaminated indoor environments. Indoor airborne fungal flora was cultured from EDCs and daily air-impaction samples collected in an office building and a daycare center. The quantitative fungal measurements obtained using a single EDC significantly correlated with the cumulative measurement of nine daily air impactions. Both methods enabled the assessment of fungal exposure, although a few differences were observed between the detected fungal species and the relative quantity of each species. EDCs were also used over a 32-month period to monitor indoor airborne fungal flora in a hospital office building, which enabled us to assess the impact of outdoor events (e.g. ground excavations) on the fungal flora levels on the indoor environment. In conclusion, EDC-based measurements provided a relatively accurate profile of the viable airborne flora present during a sampling period. In particular, EDCs provided a more representative assessment of fungal levels compared with single air-impactor sampling. The EDC technique is also simpler than performing repetitive air-impaction measures over the course of several consecutive days. EDC is a versatile tool for collecting airborne samples and was efficient for measuring mold levels in indoor environments.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Air Impaction and Electrostatic Dust Collector Sampling Methods to Assess Airborne Fungal Contamination in Public Buildings A BSTR ACT

Many ailments can be linked to exposure to indoor airborne fungus. However, obtaining a precise measurement of airborne fungal levels is complicated partly due to indoor air fluctuations and non-standardized techniques. Electrostatic dust collector (EDC) sampling devices have been used to measure a wide range of airborne analytes, including endotoxins, allergens, β-glucans, and microbial DNA in...

متن کامل

Detection of airborne Salmonella enteritidis in the environment of experimentally infected laying hens by an electrostatic sampling device.

Bacteriologic culturing of environmental samples taken from sources such as manure pits and egg belts has been the principal screening tool in programs for identifying commercial laying flocks that have been exposed to Salmonella enteritidis and are thus at risk to produce contaminated eggs. Because airborne dust and aerosols can carry bacteria, air sampling offers a potentially efficient and i...

متن کامل

Measurements of Airborne Fungal and Endotoxin Levels in Water-Damaged Buildings

Airborne fungi are often collected during the assessment of water-damaged buildings. Air sampling for endotoxin, a characteristic group of constituents of outer membranes of gram-negative bacteria, is another approach commonly used to characterize microbial conditions in buildings. This study presents results of fungal and endotoxin air samples collected in buildings with microbial complaints. ...

متن کامل

Investigating of relationship between biological and non-biological airborne particles in the internal section of two educational hospitals in Qazvin city

Background: Hospital-acquired infections, are the most important consequence in exposure to bioaerosols in which affect health of staffs and clients. The present study aimed to investigate the relationship between fungal bioaerosols and particulate matter in two educational hospitals in Qazvin city in 2017. Methods: This descriptive-analytical study, was performed in 12 of two hospitals indoor...

متن کامل

Investigation of fungi diversity in airborne dust and their sources identification in Khuzestan province

Background and Objective: Considering the fact that Iran is located in semi-arid climate and the harmful effects of dust storms on different ecosystems, this study aimed to identify and locate dust storms using fungal bio-aerosols (spores) and HYSPLIT model in southwestern region of Iran. Materials and Methods: MODIS satellite images and HYSPLIT model were used to investigate the temporal chan...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Annals of occupational hygiene

دوره 60 2  شماره 

صفحات  -

تاریخ انتشار 2016