Pii: S1010-7940(02)00035-0

نویسندگان

  • Viktor Hraška
  • A. Kántorová
  • P. Kunovský
  • D. Haviar
چکیده

Objective: The intermediate results achieved with a new technique for primary repair of tetralogy of Fallot with absent pulmonary valve syndrome are reported. Method: Apart from correction of tetralogy of Fallot, this approach includes translocation of the pulmonary artery anterior to the aorta and away from the tracheobronchial tree. Since November 1998 this technique has been employed in three symptomatic newborns and three infants with a diagnosis of tetralogy of Fallot with absent pulmonary valve. The median age at surgery was 37 days (range 14–256 days). The median weight at operation was 3.4 kg (range 2.9–4 kg). All patients had severe respiratory problems and congestive heart failure with cyanosis. Results: There was no early or late death during the follow-up (median 27 months). One patient required redo due to failure to thrive as a consequence of right ventricle volume overload. Valved conduit was inserted to pulmonary position. Respiratory symptoms disappeared or were significantly reduced in all patients. Postoperative computed tomographic scan showed no compression of trachea and main bronchi, pulmonary artery was away from tracheobronchial tree in all patients. Patients are doing well with adequate growth. Conclusions: The new technique described here has a potential to reduce or eliminate bronchial compression by pulmonary artery. Translocation of pulmonary artery anterior to the aorta takes the dilated pulmonary artery away from the trachea and bronchial tree. This approach was found to be technically feasible and can be useful especially in symptomatic newborns and infants. q 2002 Elsevier Science B.V. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pii: S1010-7940(02)00020-9

Electrocautery has a potential risk of serious pacemaker dysfunction in patients with implanted pacemaker. Here we present the safe and efficient use of ultrasonic scalpel (Harmonic scalpel) for the first time in a patient with implanted pacemaker undergoing open-heart reoperation. q 2002 Elsevier Science B.V. All rights reserved.

متن کامل

Pii: S1010-7940(02)00664-4

This report describes the formation of a true aneurysm 15 years after an internal mammary artery patch aortoplasty of an aortic coarctation. A true aneurysm was confirmed on histology. To our knowledge, this is the first report of a case with such a complication. q 2002 Published by Elsevier Science B.V.

متن کامل

Pii: S1010-7940(02)00369-x

Lipomatous hypertrophy of the interatrial septum is an uncommon entity that usually occurs in elderly patients. We report a patient who presented with atrial fibrillation, congestive cardiac failure and a large intracavitary mass in the right atrium on echocardiography. He underwent successful resection of the mass with septal reconstruction. Pathology was consistent with lipomatous hypertrophy...

متن کامل

Pii: S1010-7940(02)00349-4

Arterial pseudoaneurysm has been reported as a possible complication of immunodeficiency virus infection. We report two cases of HIVpositive patients with a pseudoaneurysm at the level of the descending thoracic aorta. The first patient refused surgery and has been followed up to 14 months, whereas the second patient underwent successful surgical repair. The importance of magnetic resonance ima...

متن کامل

Pii: S1010-7940(02)00396-2

We present rupture of lung hydatid cyst in a patient with multiple organ involvement during albendazole treatment. The patient was first provided mechanical ventilation than residue cavity and the other intact cyst was treated surgically. We concluded that albendazole should be used in postoperative period in patients with hydatid disease of the lung to prevent recurrent disease. q 2002 Elsevie...

متن کامل

Pii: S1010-7940(02)00724-8

Aortobronchial fistula is a rare complication following thoracic aortic operations and is invariably fatal if not promptly diagnosed and repaired. Direct prosthetic repair carries a risk of graft repair sepsis and fistula recurrence. We describe two cases presenting with aortobronchial fistula following coarctation repair which were successfully treated by different surgical approaches. q 2002 ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002