Low-coherence self-referencing velocimetry.
نویسندگان
چکیده
Low-coherence self-referencing velocimetry optically measures the relative velocity between a point in a particle-laden fluid and a (potentially moving) reference surface. Low-coherence light scattered off the particles and off the reference surface is coupled into an interferometer with variable optical delay in one arm and an acousto-optical modulator in the second arm. The measurement location is set relative to the reference surface. Its location can be scanned along a line by adjusting the optical delay in the interferometer. The spatial resolution is typically tens of micrometers. Only one low-coherence light beam is required for each component of the velocity vector. Proof-of-principle measurements in Taylor-Couette flow are presented.
منابع مشابه
Non-Contact Boundary Layer Profiler using Low-Coherence Self-Referencing Velocimetry
A spatially self–referencing velocimetry system based on low–coherence interferometry has been developed. The measurement technique is contactless and relies on the interference between back–reflected light from an arbitrary reference surface and seeding particles in the flow. The measurement location and the flow velocity are measured relative to the reference surface’s location and velocity, ...
متن کاملNon - contact boundary layer profiler using low - coherence self - referencing
A spatially self–referencing velocimetry system based on low–coherence interferometry has been developed. The measurement technique is contactless and relies on the interference between back–reflected light from an arbitrary reference surface and seeding particles in the flow. The measurement location and the flow velocity are measured relative to the reference surface’s location and velocity, ...
متن کاملSelf-referenced Doppler optical coherence tomography.
Doppler optical coherence tomography (DOCT) allows simultaneous micrometer-scale resolution cross-sectional imaging of tissue structure and blood flow. We demonstrate a fiber-optic polarization-diversity-based differential phase contrast DOCT system as a method to perform self-referenced velocimetry in highly scattering media. Using this strategy, we reduced common-mode interferometer noise to ...
متن کاملHeart-Brain Coherence; Heart-Rate Variability (HRV); Reading Anxiety; TestEdge Program
Based on psychophysiological research, coherent heart-brain interaction can change afferent cardiac signal pattern sent to the brain. Accordingly, the present study aimed at facilitating the emotion-cognition interaction through HeartMath Institute self-regulated emotional techniques to investigate the efficacy of heart-brain coherence on reading anxiety reduction that significantly enhances at...
متن کاملOptical coherence tomography velocimetry of colloidal suspensions.
Optical coherence tomography velocimetry combined with a rheometer and optical modulation techniques provides increased sensitivity to the low shear rate motion of complex fluid systems. Optical modulation coupled with a new interferometer design yields improved signal to noise ratios and is demonstrated with optically opaque colloidal suspensions. Thus the measurable range of shear velocities ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Optics letters
دوره 32 10 شماره
صفحات -
تاریخ انتشار 2007