Digital subtraction angiography versus real-time fluoroscopy for detection of intravascular penetration prior to epidural steroid injections: meta-analysis of prospective studies.

نویسندگان

  • Ognjen Visnjevac
  • Paul Kim
  • Sina Farid-Davari
  • Patrick Johnson
  • Nader Djalal Nader
چکیده

BACKGROUND Neurological injury is a rare but devastating complication of epidural steroid injections (ESIs) generally thought to arise from neurovascular compromise. The use of real-time fluoroscopy (RTF) with contrast media is the most common preventative measure taken to avoid intravascular penetration. In 2002, it was proposed that digital subtraction angiography (DSA) might be more useful than RTF. Since then, several prospective studies have advocated for its use. OBJECTIVES As DSA is not currently a "gold standard," a meta-analysis was performed to compare the efficacy of DSA versus RTF for detection of intravascular penetration during ESI. STUDY DESIGN Meta-analysis of prospective observational studies. METHODS A targeted Pubmed search was conducted, yielding 49 reports and 4 manuscripts, which were analyzed using Review Manager Software (Rev Man 5.2). Inclusion/exclusion criteria: peer-reviewed prospective reports comparing the sensitivity of DSA to RTF in the same individuals without change in needle position between comparative imaging. Pooled estimate of odds ratios with 95% confidence interval using a random effect model was applied. RESULTS There were a total of 188 intravascular events from 1,290 ESIs performed. RTF was able to detect 148 events with DSA detecting an additional 40 events missed by RTF. No major neurological complications were reported. DSA had a statistically significant favorable odds ratio over RTF for detection of intravascular penetration during ESI (OR = 1.32 [1.05 - 1.67]; P = 0.02). LIMITATIONS Although the major methodological aspects of each study assessed in this meta-analysis were quite similar, there were small differences in needle gauge and the selection of secondary outcome measures. Despite attempts to minimize it, concern for operator bias also exists. CONCLUSIONS DSA had a 32% improvement (OR = 1.32) for detection of intravascular penetration with ESI when compared to RTF. Although this supports advocacy for use of DSA, it also suggests that there is a greater than 30% "missed-events" rate for detection of vascular penetration when using RTF for ESI, which does not correlate with the generally reported cumulative rates of complications (1%). This discrepancy suggests that factors other than vascular events also play a role in complications. Nonetheless, given the evidence, we advocate for the increased use of DSA over RTF for transformational ESIs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Digital Subtraction Angiography Use During Epidural Steroid Injections Does Not Reliably Distinguish Artery from Vein.

BACKGROUND Epidural steroid injections (ESIs) are among the most common procedures performed in an interventional pain management practice. It is well known that tragic complications may arise from ESIs, most commonly those performed using a transforaminal approach. Digital subtraction angiography (DSA) has been hailed as a fluoroscopic technique that can be used to detect arterial placement of...

متن کامل

Intravascular flow detection during transforaminal epidural injections: a prospective assessment.

BACKGROUND Transforaminal epidural steroid injections (TFESI) are a mainstay in the treatment of spine pain. Though this commonly performed procedure is generally felt to be safe, devastating complications following inadvertent intra-arterial injections of particulate steroid have been reported. The use of digital subtraction angiography (DSA) has been suggested as a means of detecting intra-ar...

متن کامل

Utility of Digital Subtraction Angiography in Cervical Transforaminal Epidural Steroid Injections: Does Digital Subtraction Improve Safety Over Live Fluoroscopy? -

919 Scientific abstract: Chronic pain Utility of Digital Subtraction Angiography in Cervical Transforaminal Epidural Steroid Injections: Does Digital Subtraction Improve Safety Over Live Fluoroscopy? Andrew Rubens, Carlos A. Pino, Clarence Ivie The University of Vermont Medical Center Introduction Cervical transforaminal epidural steroid injections (CTFESI) have been used for many years in the ...

متن کامل

Comparison of incidence of intravascular injections during transforaminal epidural steroid injection using different needle types

BACKGROUND Infrequent but serious complications of transforaminal epidural steroid injection (TFESI) occur due to inadvertent intravascular injections. A few studies reported that the different needle types can influence on the occurrences of intravascular incidence in TFESI. This study prospectively evaluated whether short-bevel needle can reduce the incidences of intravascular injection of TF...

متن کامل

Accuracy of Live Fluoroscopy to Detect Intravascular Injection During Lumbar Transforaminal Epidural Injections

BACKGROUND Complications following lumbar transforaminal epidural injection are frequently related to inadvertent vascular injection of corticosteroids. Several methods have been proposed to reduce the risk of vascular injection. The generally accepted technique during epidural steroid injection is intermittent fluoroscopy. In fact, this technique may miss vascular uptake due to rapid washout. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Pain physician

دوره 18 1  شماره 

صفحات  -

تاریخ انتشار 2015