Patient-ventilator interaction and sleep in mechanically ventilated patients: pressure support versus proportional assist ventilation.

نویسندگان

  • Karen Bosma
  • Gabriela Ferreyra
  • Cristina Ambrogio
  • Daniela Pasero
  • Lucia Mirabella
  • Alberto Braghiroli
  • Lorenzo Appendini
  • Luciana Mascia
  • V Marco Ranieri
چکیده

OBJECTIVES To understand the role of patient-ventilator asynchrony in the etiology of sleep disruption and determine whether optimizing patient-ventilator interactions by using proportional assist ventilation improves sleep. DESIGN Randomized crossover clinical trial. SETTING A tertiary university medical-surgical intensive care unit. PATIENTS Thirteen patients during weaning from mechanical ventilation. INTERVENTIONS Patients were randomized to receive pressure support ventilation or proportional assist ventilation on the first night and then crossed over to the alternative mode for the second night. Polysomnography and measurement of light, noise, esophageal pressure, airway pressure, and flow were performed from 10 pm to 8 am. Ventilator settings (pressure level during pressure support ventilation and resistive and elastic proportionality factors during proportional assist ventilation) were set to obtain a 50% reduction of the inspiratory work (pressure time product per minute) performed during a spontaneous breathing trial. MEASUREMENTS AND MAIN RESULTS Arousals per hour of sleep time during pressure support ventilation were 16 (range 2-74) and 9 (range 1-41) during proportional assist ventilation (p = .02). Overall sleep quality was significantly improved on proportional assist ventilation (p < .05) due to the combined effect of fewer arousals per hour, fewer awakenings per hour (3.5 [0-24] vs. 5.5 [1-24]), and greater rapid eye movement (9% [0-31] vs. 4% [0-23]), and slow wave (3% [0-16] vs. 1% [0-10]) sleep. Tidal volume and minute ventilation were lower on proportional assist ventilation, allowing for a greater increase in Paco2 during the night. Patient-ventilator asynchronies per hour were lower with proportional assist ventilation than with pressure support ventilation (24 +/- 15 vs. 53 +/- 59; p = .02) and correlated with the number of arousals per hour (R = .65, p = .0001). CONCLUSIONS Patient ventilator discordance causes sleep disruption. Proportional assist ventilation seems more efficacious than pressure support ventilation in matching ventilatory requirements with ventilator assistance, therefore resulting in fewer patient-ventilator asynchronies and better quality of sleep.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Proportional assist ventilation (PAV): a significant advance or a futile struggle between logic and practice?

Proportional assist ventilation is a promising addition to other more conventional modes of mechanical ventilation with the theoretical advantage of improving patient-ventilator interaction. It may also be of use as a diagnostic tool in the control of breathing in mechanically ventilated patients.

متن کامل

Sleep quality in mechanically ventilated patients: comparison between NAVA and PSV modes

BACKGROUND Mechanical ventilation seems to occupy a major source in alteration in the quality and quantity of sleep among patients in intensive care. Quality of sleep is negatively affected with frequent patient-ventilator asynchronies and more specifically with modes of ventilation. The quality of sleep among ventilated patients seems to be related in part to the alteration between the capacit...

متن کامل

New modalities for non-invasive positive pressure ventilation: A review article

Efficiency of non-invasive positive pressure ventilation in the treatment of respiratory failure has been shown in many published studies. In this review article, we introduced new modalities of non-invasive ventilation (NIV), clinical settings in which NIV can be used and a practical summary of the latest official guidelines published by the European Respiratory Clinical Practice. Clinical tri...

متن کامل

Impact of prolonged assisted ventilation on diaphragmatic efficiency: NAVA versus PSV

BACKGROUND Prolonged controlled mechanical ventilation depresses diaphragmatic efficiency. Assisted modes of ventilation should improve it. We assessed the impact of pressure support ventilation versus neurally adjusted ventilator assist on diaphragmatic efficiency. METHOD Patients previously ventilated with controlled mechanical ventilation for 72 hours or more were randomized to be ventilat...

متن کامل

0989. Accuracy of delivered airway pressure during proportional assist ventilation +. A bench study

Introduction Proportional assist ventilation (PAV+) is a partial ventilatory support mode delivering airway pressure (Paw) in proportion to patient effort, enhancing patient-ventilator interactions. The ventilator estimates muscular pressure by using the respiratory system equation of motion with the instantaneous volume (V) and flow (V ́) and the automatically calculated compliance and resistan...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Critical care medicine

دوره 35 4  شماره 

صفحات  -

تاریخ انتشار 2007