High Performance Gel Permeation Chromatography of Polymers
نویسنده
چکیده
The determination of the molecular weight distribution by gel permeation chromatography requires the establishment of a molecular weight calibration and efficient columns in order to minimise chromatogram broadening. The separation process is described in terms of steric exclu— sion, retardation and partial exclusion mechanisms in order to show how the universal calibration method may be influenced by solute-gel interactions. Solute dispersion mechanisms are described to show how chromat— ogram broadening is determined by the particle size of the column packing, the eluent flow rate, and the solute diffusion coefficient. Consequently, extensive chromatogram broadening will occur for permeating high polymers at fast flow rates, the decrease in column efficiency with flow rate becoming more significant as solute size rises. Therefore, accurate mole— cular weight distributions may be determined by high performance gel permeation chromatography with microparticulate packings at low eluent flow rates. For small molecules efficient separations occur at fast flow rates, so that high speed and high resolution separations of prepolymers and low polymers may be performed by gel permeation chromatography.
منابع مشابه
Chemical modification of maleic anhydride polymers with carbazole
Maleic anhydride (MAN) copolymers with methyl methacrylate(MMA), ethyl methacrylate(EMA), methyl acrylate(MA), ethyl acrylate (EA) and buthyl acrylate (BA) ( in a 1:1 mole ratio) were synthesized by free radical polymerizations method under vacuum -azobis(isobutironitrile)(AIBN) as an initiator of reaction at 701C. The copolymer compositions were determined using related 1H NMR spectra techni...
متن کاملFractionation and characterization of phenolic resins by high-performance liquid chromatography and gel-permeation chromatography combined with ultraviolet, refractive index, mass spectrometry and light-scattering detection.
HPLC and gel permeation chromatographic (GPC) characterization of complex phenol-formaldehyde resins is described. Reversed-phase HPLC fingerprints the phenolic monomers, dimers and some oligomers. The molecular masses of these phenolic compounds were determined using an ion trap mass spectrometer. GPC analyzes tetrahydrofuran-soluble phenolic polymers beyond HPLC capability. The molecular mass...
متن کاملAnalysis of flame retardant additives in polymer fractions of waste of electric and electronic equipment (WEEE) by means of HPLC-UV/MS and GPC-HPLC-UV.
An HPLC-UV/MS method has been developed to identify and quantify flame retardants in post-consumer plastics from waste of electric and electronic equipment (WEEE). Atmospheric pressure chemical ionisation spectra of 15 brominated and phosphate-based flame retardants were recorded and interpreted. The method was applied to detect flame retardant additives in polymer extracts obtained from pressu...
متن کاملGel permeation chromatography coupled to fourier transform mass spectrometry for polymer characterization.
We report an on-line coupling of gel permeation chromatography (GPC) to Fourier transform mass spectrometry (FTMS) using a modified commercial electrospray ionization (ESI) interface. Selected oligomer profiles for the sodiated (1+ through 5+ charge states) oligomer ions of a narrow-molecular-weight poly(methyl methacrylate) were generated and used for obtaining a calibration curve. Using the M...
متن کاملSynthesis of High Performance Cyclic Olefin Polymers (COPs) with Ester Group via Ring-Opening Metathesis Polymerization
Novel ester group functionalized cyclic olefin polymers (COPs) with high glass transition temperature, high transparency, good mechanical performance and excellent film forming ability have been achieved in this work via efficient ring-opening metathesis copolymerization of exo-1,4,4a,9,9a,10-hexahydro-9,10(1′,2′)-benzeno-l,4-methanoanthracene (HBM) and comonomers (5-norbornene-2-yl methylaceta...
متن کامل