Could MRI and CT Scanners Be Operated More Intensively in Canada?
نویسندگان
چکیده
Although availability of necessary equipment could play a role in wait times for MRI and CT exams in Canada, there are other dimensions to this issue. More machines in operation do not necessarily reduce wait times. It is important also to consider the level of utilization of the existing pool of scanners.This paper analyzes utilization of MRI and CT scanners (machines) by focusing on two indicators: the number of exams per machine per year and the number of hours of operation per machine per week. These values were calculated and reported by province, followed by an assessment of the average level of utilization of MRI and CT scanners in Canada. The findings suggest that some provinces use their MRI or CT scanners less intensively than others. On average, in Canada, an additional 31% operating capacity may exist for MRI and 68% for CT without additional capital or infrastructure investments. However, supply-side as well as demand-side constraints may prevent a given jurisdiction from operating at full capacity.
منابع مشابه
Evaluation of MRI-based Polymer Gel Dosimetry for Measurement of CT Dose Index (CTDI) on 64 slices CT Scanners
Introduction: Computed tomography (CT) has numerous applications in clinical procedures but its main problem is its high radiation dose to the patients compared to other imaging modalities using x-ray. CT delivers approximately high doses to the nearby tissues due to the scattering effect, fan beam (beam divergence) and limited collimator efficiency. The radiation dose from multi-slice scanners...
متن کاملDose Reduction Methods in Chest Computed Tomography
Introduction: Computed tomography is one of the most powerful tools for investigating thorax disease, because it shows progression of lung disease much clearer than chest radiography. Technical advances in CT scanners have led to some abilities for CT scanners such as coverage of larger volume, lower noise and ability for acquiring image in one respiratory phase. However, this will be accompani...
متن کاملEvaluation of Diagnostic Value of CT Scan and MRI in Brain Tumors and Comparison with Biopsy
Abstract Background Cerebral neoplasm arises from brain, spinal cord and meningeal cells. Not only malignant cerebral neoplasm also benign tumor could lead to death due to mass effect on vital structures. Access to these tumors is difficult, and MRI and CT scan could be helpful in determining anatomical location of tumors and distinction of malignant from benign. Objective For better and ea...
متن کاملIs a negative cranial CT-scan adequate to support a diagnosis of pseudotumor cerebri
In a patient with features indicating the presence of pseudotumor cerebri, a negative cranial CT-scan is not adequate to rule out less benign pathology and an MRI of brain should be performed. In this study, a 10-year old boy with daily headaches for one month and diplopia for one week was found to have a partial abducens palsy and bilateral papilledema; otherwise, his examination was normal. A...
متن کاملIs a negative cranial CT-scan adequate to support a diagnosis of pseudotumor cerebri
In a patient with features indicating the presence of pseudotumor cerebri, a negative cranial CT-scan is not adequate to rule out less benign pathology and an MRI of brain should be performed. In this study, a 10-year old boy with daily headaches for one month and diplopia for one week was found to have a partial abducens palsy and bilateral papilledema; otherwise, his examination was normal. A...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Healthcare policy = Politiques de sante
دوره 3 1 شماره
صفحات -
تاریخ انتشار 2007