Long-term epicardial ventricular pacing from endocardial bipolar pacemaker lead: perforation of right atrial wall.
نویسندگان
چکیده
One of the hazards of endocardial cardiac pacing is that the pacemaker lead may perforate the myocardial wall or interventricular septum although the incidence of such perforations is believed to be small. This paper describes what is believed to be a unique case in which a pacemaker lead perforated the atrial wall at implantation (or possibly shortly afterwards) and yet gave satisfactory right ventricular epicardial pacing for more than five years. The perforation was discovered during a routine postmortem examination but earlier lateral x-ray examinations would probably have identified the abnormal position of the electrodes. Moreover, the present implantation technique would not have allowed perforation of the atrial wall at implantation to go undetected.
منابع مشابه
Effectiveness of epicardial atrial pacing using a bipolar steroid-eluting endocardial lead with active fixation in an experimental model
PURPOSE To assess the effectiveness of bipolar epicardial atrial pacing using an active fixation bipolar endocardial lead implanted on the atrial surface in an experimental model. METHODS A total of ten Large White adult pigs underwent pacemaker implantation under general anesthesia. Atrial pacing and sensing parameters were obtained at the procedure, immediate postoperative period and on the...
متن کاملLong-term outcomes of cardiac pacing in adults with congenital heart disease.
OBJECTIVES The purpose of this retrospective study was to define long-term outcomes after pacemaker therapy in adults with congenital heart disease (CHD). BACKGROUND Adults with CHD represent a unique and expanding population. Many will require pacemaker or implantable defibrillator therapy, with a lifelong need for re-intervention and follow-up. They pose technical and management challenges ...
متن کاملRadial Multi-Site, Longitudinal Multi-Polar Epicardial Left Ventricular Pacing In Tricuspid Valve Disease
Tricuspid valve (TV) disease (which includes surgical repair) can impede transvenous endocardial right ventricular pacing. A lead crossing the TV can damage and be damaged by the valve, especially in the presence of mechanical prostheses (valve, annuoplasty ring, artificial chordae). Surgical epicardial lead placement requires sternotomy or thoracotomy and pericardotomy, with associated morbidi...
متن کاملValidation of the mapping accuracy of a novel non-invasive epicardial and endocardial electrophysiology system
AIMS Use of a non-invasive electrocardiographic mapping system may aid in rapid diagnosis of atrial or ventricular arrhythmias or the detection of ventricular dyssynchrony. The aim of the present study was to validate the mapping accuracy of a novel non-invasive epi- and endocardial electrophysiology system (NEEES). METHODS AND RESULTS Patients underwent pre-procedural computed tomography or ...
متن کاملContralateral pneumothorax after cardiac pacemaker implantation
We report a case of a 73-year-old man, who was scheduled for elective dual chamber pacemaker implantation because of paroxysmal second-degree atrioventricular block. The pacemaker pocket was located in the left in-fraclavicular fossa. An active fixation ventricular lead was implanted into the right ventricular outflow tract (RVOT) through the left cephalic vein venesection, while another active...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Thorax
دوره 32 3 شماره
صفحات -
تاریخ انتشار 1977