Intraocular Lens Multifocality Combined with the Compensation for Corneal Spherical Aberration: A New Concept of Presbyopia-Correcting Intraocular Lens
نویسنده
چکیده
The outcomes of a prospective consecutive study aimed at evaluating the visual and refractive benefit after cataract surgery with the implantation of the aspheric diffractive multifocal intraocular lens (IOL) Tecnis ZMB00 (Abbott Medical Optics) are reported. A total of 31 eyes of 19 patients (age range, 40 to 81 years) underwent phacoemulsification surgery with implantation of this aspheric multifocal IOL. At 6 months after surgery, postoperative spherical equivalent was within ±1.00 D in 96.8% of eyes, with 94.7% of patients presenting a postoperative binocular far LogMAR uncorrected visual acuity (UCVA) of 0.1 or better. Far best-corrected distance VA improved significantly (p < 0.01), with postoperative values of 0.1 or better in 96.8% of eyes. Postoperative near UCVA was 0.10 (equivalent to J1) or better in 93.55% of eyes. Furthermore, the IOL power was found to be very poorly correlated with the postoperative far LogMAR (r = 0.13) and near UCVA (r = 0.13). In conclusion, the aspheric diffractive multifocal IOL Tecnis ZMB00 provides a restoration of the far and near visual function after phacoemulsification surgery for cataract removal or presbyopia correction, which is predictable and independent from the optical power of the implanted IOL.
منابع مشابه
Patient acceptability of the Tecnis® multifocal intraocular lens
Cataract surgery has evolved. The goal of the surgeon includes both restoration of vision and refinement of vision. Patients' desire for spectacle independence has driven the market for presbyopia-correcting cataract surgery and development of novel intraocular lens (IOL) designs. The Tecnis(®) Multifocal Intraocular Lens incorporates an aspheric, modified anterior prolate IOL with a diffractiv...
متن کاملIn vitro strehl ratios with spherical, aberration-free, average, and customized spherical aberration-correcting intraocular lenses.
PURPOSE To determine in vitro image qualities of artificial eyes achieved with spherical, aberration-free, average spherical aberration-correcting, and customized spherical aberration-correcting IOLs in centered, decentered, and tilted positions. METHODS The in vitro performance of these IOL models was determined by optical bench measurements. The experimental setup included a laser light sou...
متن کاملMultifocal intraocular lens providing optimized through-focus performance.
A widespread type of multifocal intraocular lens (MIOL) is based on expanding the depth of focus with specific amounts of spherical aberration. However, knowing the optimal wavefront aberration for multifocality does not directly provide a MIOL geometry. To overcome this issue, we present a new strategy to design MIOLs. The method optimizes directly the IOL surface geometries (aspheres with asp...
متن کاملOptical aberrations of intraocular lenses measured in vivo and in vitro.
Corneal and ocular aberrations were measured in a group of eyes before and after cataract surgery with spherical intraocular lens (IOL) implantation by use of well-tested techniques developed in our laboratory. By subtraction of corneal from total aberration maps, we also estimated the optical quality of the intraocular lens in vivo. We found that aberrations in pseudophakic eyes are not signif...
متن کاملBalance of corneal horizontal coma by internal optics in eyes with intraocular artificial lenses: Evidence of a passive mechanism
It is well known that the aberrations of the cornea are partially compensated by the aberrations of the internal optics of the eye (primarily the crystalline lens) in young subjects. This effect has been found not only for the spherical aberration, but also for horizontal coma. It has been debated whether the compensation of horizontal coma is the result of passive mechanism [Artal, P., Benito,...
متن کامل