Non-uniform Illumination Correction in Transmission Electron Microscopy

نویسندگان

  • Tolga Tasdizen
  • Elizabeth Jurrus
  • Ross T. Whitaker
چکیده

Transmission electron microscopy (TEM) provides resolutions on the order of a nanometer. Hence, it is a critical imaging modality for biomedical analysis at the sub-cellular level. One of the problems associated with TEM images is variations in brightness due to electron imaging defects or non-uniform support films and specimen staining. These variations render image processing operations such as segmentation more difficult. The correction requires estimation of the global illumination field. In this paper, we propose an automatic method for estimating the illumination field using only image intensity gradients. The closed-form solution is very fast to compute.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automatic Correction of Non-uniform Illumination in Transmission Electron Microscopy Images

Transmission electron microscopy (TEM) provides resolutions on the order of a nanometer. Hence, it is a critical imaging modality for biomedical analysis at the cellular level. One of the problems associated with TEM images is variations in brightness due to electron imaging defects or nonuniform support films and specimen staining. These variations render image processing operations such as se...

متن کامل

Low-dose aberration corrected cryo-electron microscopy of organic specimens.

Spherical aberration (C(s)) correction in the transmission electron microscope has enabled sub-angstrom resolution imaging of inorganic materials. To achieve similar resolution for radiation-sensitive organic materials requires the microscope to be operated under hybrid conditions: low electron dose illumination of the specimen at liquid nitrogen temperature and low defocus values. Initial imag...

متن کامل

Attenuation correction in myocardial perfusion SPECT using sequential transmission - emission scanning with 99mTc [Persain]

Introduction: Nowadays, Imaging of the myocardial perfusion (MPI) using the single photon emission tomography (SPET) in the diagnosis of coronary artery disease, especially myocardial ischemia, is of great importance. In contrast to the coronary artery angiography, MPI is non-invasive, less expensive and more physiological. Unfortunately, this image is affected by the some artifacts. Thes...

متن کامل

Synthesis of nanocrystalline BaTiO3 ceramics via hydrothermal condition and structural characterization by HRTEM and SAED

In the present work, we report a suitable approach for the preparation of BaTiO3 nanostructures via the hydrothermal condition using Dolapix ET85 as surfactant. The powders were investigated by X-ray diffraction (XRD), scanning election microscopy (SEM), energy-dispersive X-ray spectroscopy (EDAX), field emission transmission electron microscopy (FETEM), selected area electron diffra...

متن کامل

Ex-situ studies on calcinations of structural, optical and morphological properties of post-growth nanoparticles CeO2 by HRTEM and SAED

Nanocrystalline particles of Cerium Oxide (CeO2) have been prepared by the chemical precipitation method using Cerium nitrate and Urea with a molar ratio of 1:2. The results revealed that the formation of CeO2 fine particles is influenced by molar ratio of metal nitrates to fuel. Well faceted CeO2 nanoparticles, were synthesized by thermal-assisted dissociation ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008