PURPOSE To investigate whether an overlap volume histogram (OVH)-driven planning application using an intensity-modulated radiation therapy (IMRT) database can guide and automate volumetric-modulated arc therapy (VMAT) planning for head-and-neck cancer. METHODS Based on comparable head-and-neck dosimetric results between planner-generated VMAT and IMRT plans, an inhouse developed, OVH-driven automated planning application containing a database of prior clinical head-and-neck IMRT plans is built into Pinnacle(3) SmartArc for VMAT planning. Double-arc VMAT plans of four oropharynx, four nasopharynx, and four larynx patients are generated and compared with corresponding clinical IMRT plans. RESULTS Each VMAT plan is automatically generated in two optimization rounds, while the average number of optimization rounds in generating a clinical IMRT plan is 43. In VMAT plans, statistical superiority (p < 0.01) in sparing of the cord+4 mm, brainstem, brachial plexus, larynx, and inner ear is observed with a slight degradation in low-dose-level planning target volume (PTV) coverage. On average, D(0.1 cc) to the cord+4 mm, brainstem and brachial plexus is reduced by 3.7, 4.9, and 1.6 Gy, respectively; V(50 Gy) to the larynx is reduced by 5.3%; mean dose to the inner ear is reduced by 4.4 Gy; V(95) of low-dose-level PTV coverage is reduced by 0.3% with p = 0.25. CONCLUSIONS IMRT-data-driven VMAT planning offers a potential method for generating VMAT plans that are comparable to IMRT plans in terms of dosimetric quality.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Efficiency of biological versus physical optimization for single‐arc VMAT for prostate and head and neck cases

The aim of this work was to compare different approaches to VMAT optimization (biological vs. physical DVH-based) in two commercial treatment planning systems (TPS) for head and neck and prostate cases, using Pareto fronts. VMAT vs. IMRT Pareto front comparison was additionally performed in order to benchmark the optimizer efficiency and VMAT plan quality for each TPS. Three prostate and three ...

متن کامل

The effect of high energy photon beam in dose- volume parameters and integral dose of normal structures in Head and neck IMRT

Introduction: The aim of this study is to investigate the effect of partially used high photon energies on dosimetric parameters and integral doses of nasopharynx IMRT plans.   Materials and Methods: Two 7 coplanar IMRT plan were created for eleven patients (6 MV only IMRT plan in both phase1 and phase2 and 6 MV phase1-mixed energies (6 MV and 15 MV) phase2...

متن کامل

Dose Distribution Analysis of Rapid Arc and Intensity Modulated Radiotherapy Plan in Head and Neck Cancer

Introduction: Globally, intensity-modulated radiation therapy (IMRT) is considered as highly precise and accurate method of radiotherapy planning. This technique amplifies spatial dose distribution conformity by modulating the intensity of radiation beams in each sub-volume. Additionally, it can reduces the dose to surrounding critical organs and deliver the planned dose to targets with the nom...

متن کامل

Application of AAPM TG 119 to volumetric arc therapy (VMAT)

The purpose of this study was to create AAPM TG 119 benchmark plans for volumetric arc therapy (VMAT) and to compare VMAT plans with IMRT plan data. AAPM TG 119 proposes a set of test clinical cases for testing the accuracy of IMRT planning and delivery system. For these test cases, we generated two treatment plans, the first plan using 7-9 static dMLC IMRT fields and a second plan utilizing on...

متن کامل

Evaluation of volumetric modulated arc therapy (VMAT) with Oncentra MasterPlan® for the treatment of head and neck cancer

BACKGROUND Several comparison studies have shown the capability of VMAT to achieve similar or better plan quality as IMRT, while reducing the treatment time. The experience of VMAT in a multi vendor environment is limited. We compared the plan quality and performance of VMAT to IMRT and we investigate the effects of varying various user-selectable parameters. METHODS IMRT, single arc VMAT and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 40 2  شماره 

صفحات  -

تاریخ انتشار 2013