Propeller EPI in the other direction.

نویسندگان

  • Stefan Skare
  • Rexford D Newbould
  • Dave B Clayton
  • Roland Bammer
چکیده

A new propeller EPI pulse sequence with reduced sensitivity to field inhomogeneities is proposed. Image artifacts such as blurring due to Nyquist ghosting and susceptibility gradients are investigated and compared with those obtained in previous propeller EPI studies. The proposed propeller EPI sequence uses a readout that is played out along the short axis of the propeller blade, orthogonal to the readout used in previous propeller methods. In contrast to long-axis readout propeller EPI, this causes the echo spacing between two consecutive phase-encoding (PE) lines to decrease, which in turn increases the k-space velocity in this direction and hence the pseudo-bandwidth. Long- and short-axis propeller EPI, and standard single-shot EPI sequences were compared on phantoms and a healthy volunteer. Diffusion-weighted imaging (DWI) was also performed on the volunteer. Short-axis propeller EPI produced considerably fewer image artifacts compared to the other two sequences. Further, the oblique blades for the long-axis propeller EPI were also prone to one order of magnitude higher residual ghosting than the proposed short-axis propeller EPI.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Efficient Correction Technique for Constant, Linear and ‘Oblique’ Phase Errors in EPI-PROPELLER

Introduction Short-axis and long-axis PROPELLER echo planar imaging (referred to as SAP-EPI and LAP-EPI, respectively) [1, 2] have been developed as alternatives to fast spin echo (FSE)-based PROPELLER sequences [3]. EPI-PROPELLER typically requires fewer shots than FSE-PROPELLER, and is less SAR-intensive. Like other EPI sequences, however, both SAPand LAP-EPI are sensitive to eddy currents th...

متن کامل

Reduction of Aliasing Artifacts in Diffusion-Weighted PROPELLER Imaging

Introduction Diffusion imaging is typically performed in axial planes. This is largely due to its reliance on single-shot echo-planar imaging (EPI) which suffers from increased image distortion in sagittal and coronal planes because of concomitant gradient fields [1-2], especially with strong gradients and/or at relatively low B0-fields (including 1.5T). Diffusion-weighted (DW) imaging in non-a...

متن کامل

Effects of b-Matrix Correction on Fiber Tractography in High Resolution DTI with Short-Axis Propeller EPI

INTRODUCTION –Short-Axis Propeller EPI (SAP-EPI) has been shown to be very effective in obtaining highresolution, artifact-free DTI data [2]. One challenge with SAP-EPI is that in the presence of head rotation each blade of SAP-EPI data is potentially encoded with a different diffusionencoding direction (i.e. b-matrix) (Fig. 1). Since the diffusion-encoding is ‘imprinted’ on the magnetization, ...

متن کامل

PROPELLER-EPI with parallel imaging using a circularly symmetric phased-array RF coil at 3.0 T: application to high-resolution diffusion tensor imaging.

A technique integrating multishot periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) and parallel imaging is presented for diffusion echo-planar imaging (EPI) at high spatial resolution. The method combines the advantages of parallel imaging to achieve accelerated sampling along the phase-encoding direction, and PROPELLER acquisition to further decrease the...

متن کامل

Diffusion weighted image domain Propeller EPI (DW iProp EPI)

Introduction Geometric distortions in Echo Planar Imaging (EPI) are dependent on two sequence parameters: the phase encoding FOV and the echo spacing between two consecutive ky lines, both of which affect the k-space traversal speed. Assuming that a maximum readout gradient bandwidth is used, the echo spacing can be reduced by decreasing the resolution in the kx (not ky!) direction. Both Short ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 55 6  شماره 

صفحات  -

تاریخ انتشار 2006