Analysis of Patients' X-ray Exposure in 146 Percutaneous Radiologic Gastrostomies.

نویسندگان

  • Tim-Ole Petersen
  • Martin Reinhardt
  • Jochen Fuchs
  • Dieter Gosch
  • Alexey Surov
  • Patrick Stumpp
  • Thomas Kahn
  • Michael Moche
چکیده

Purpose Analysis of patient´s X-ray exposure during percutaneous radiologic gastrostomies (PRG) in a larger population. Materials and Methods Data of primary successful PRG-procedures, performed between 2004 and 2015 in 146 patients, were analyzed regarding the exposition to X-ray. Dose-area-product (DAP), dose-length-product (DLP) respectively, and fluoroscopy time (FT) were correlated with the used x-ray systems (Flatpanel Detector (FD) vs. Image Itensifier (BV)) and the necessity for periprocedural placement of a nasogastric tube. Additionally, the effective X-ray dose for PRG placement using fluoroscopy (DL), computed tomography (CT), and cone beam CT (CBCT) was estimated using a conversion factor. Results The median DFP of PRG-placements under fluoroscopy was 163 cGy*cm2 (flat panel detector systems: 155 cGy*cm2; X-ray image intensifier: 175 cGy*cm2). The median DLZ was 2.2 min. Intraprocedural placement of a naso- or orogastric probe (n = 68) resulted in a significant prolongation of the median DLZ to 2.5 min versus 2 min in patients with an already existing probe. In addition, dose values were analyzed in smaller samples of patients in which the PRG was placed under CBCT (n = 7, median DFP = 2635 cGy*cm2), or using CT (n = 4, median DLP = 657 mGy*cm). Estimates of the median DFP and DLP showed effective doses of 0.3 mSv for DL-assisted placements (flat panel detector 0.3 mSv, X-ray image converter 0.4 mSv), 7.9 mSv using a CBCT - flat detector, and 9.9 mSv using CT. This corresponds to a factor 26 of DL versus CBCT, or a factor 33 of DL versus CT. Conclusion In order to minimize X-ray exposure during PRG-procedures for patients and staff, fluoroscopically-guided interventions should employ flat detector systems with short transmittance sequences in low dose mode and with slow image frequency. Series recordings can be dispensed with. The intraprocedural placement of a naso- or orogastric probe significantly extends FT, but has little effect on the overall dose of the intervention. Due to the significantly higher X-ray exposure, the use of a CBCT as well as PRG-placements using CT should be limited to clinically absolutely necessary exceptions with strict indication. Key Points  · Fluoroscopically-guided PRG placements are interventions with low X-ray exposure.. · X-ray exposure from fluoroscopy is lower using flat panel detector systems as compared to image intensifier systems.. · The concomitant placement of an oro- or nasogastric probe extends the fluoroscopy time.. · Gastric probe placement is worthwhile to prevent the premature use of the significantly radiation-intensive CT.. · The use of the C-arm CT or the CT increases the beam exposure by 26 or 33 times, respectively.. · The PRG placement using C-arm CT and CT should only be performed in exceptional cases.. Citation Format · Petersen TO, Reinhardt M, Fuchs J et al. Analysis of Patients' X-ray Exposure in 146 Percutaneous Radiologic Gastrostomies. Fortschr Röntgenstr 2017; 189: 820 - 827.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Percutaneous endoscopic gastrostomy reduces total hospital costs in head-injured patients.

BACKGROUND Gastrostomies provide reliable long-term enteral access in patients with traumatic brain injuries. The impact of technique of gastrostomy on total hospital cost is not known. METHODS A retrospective analysis of patients who sustained head trauma and required gastrostomies for long-term enteral access between 1 July 1990 and 1 July 1996 was performed. RESULTS The patients who rece...

متن کامل

Late-onset Radiologic Findings of Respiratory System Following Sulfur Mustard Exposure

Background: Sulfur mustard (SM) as a chemical warfare agent, increases permeability of bronchial vessels and damages airway epithelium. SM exposure causes debilitating respiratory complications. This study was designed to evaluate clinical respiratory manifestations, and to compare chest X ray (CXR) and high resolution computed tomography (HRCT) scan of chest in SM exposed patients with respira...

متن کامل

Radiologic Manifestations of Patients with Smear Positive Pulmonary Tuberculosis in Zabol

Background & Aims: Tuberculosis is one of the most important causes of mortality in the world and if it is not treated, 50 – 65% of patients would die in five years. Chest X-ray has an important role in the diagnosis of TB and early diagnosis and treatment prevent tuberculosis transmission. In this study we evaluated radiologic manifestations of patients with smear positive pulmonary tubercu...

متن کامل

Percutaneous radiologic gastrostomy: results and complications.

BACKGROUND Percutaneous endoscopic gastrostomy is usually difficult in patients with malignant involvement of oral cavity, pharynx and esophagus. Flouroscopic guided insertion of Gastrostomy catheter with Gastropexy have gained acceptance because it is easy and less time consuming as well as less invasive as compare to surgical procedure. This study was done to evaluate the safety and efficacy ...

متن کامل

بررسی نتایج درمان سنگهای کلیه و حالب فوقانی بروش PCNL بدون استفاده از فلوروسکوپ در بیمارستان اکباتان همدان

The prevalence of urinary tract stone disease is estimated to be 2-3%. There is not any absolute prophylactic and medical therapeutic measure for urinary stone disease. But there is significant improvement in minimally invasive surgical techniques for stone removal. PCNL (Percutaneous Nephro Lithotripsy) is a minimally invasive and safe technique to treat the urinary &...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin

دوره 189 9  شماره 

صفحات  -

تاریخ انتشار 2017