Effect of Concentration on Median Effective Dose (ED50) for Motor Block of Intrathecal Plain Bupivacaine in Elderly Patients

نویسندگان

  • Ming-quan Chen
  • Zhong-yuan Xia
چکیده

BACKGROUND The aim of the study was to determine the median effective dose (ED50) for motor block of various concentrations of intrathecally administered plain bupivacaine. MATERIAL AND METHODS Between 2011 and 2013, 64 patients aged ≥70 years, undergoing transurethral, or lower limb surgery with combined spinal and epidural anesthesia in a single hospital were enrolled. The patients were randomized into 3 groups to receive intrathecal 0.75% bupivacaine (Group 1), 0.375% bupivacaine (Group 2) or 0.25% bupivacaine (Group 3). Spinal anesthesia was achieved using injections of up-and-down doses of 0.75%, 0.375%, or 0.25% plain bupivacaine. The first patient in each group received 7.5 mg bupivacaine, and the testing interval was set at 0.75 mg. The efficacy of motor block in both legs was determined using a modified Bromage and a hip motor function scale. The ED50 for motor block was estimated according to the Dixon's up-and-down method. RESULTS The ED50 for motor block of bupivacaine was 6.10 (95% CI 5.58-6.66) mg in Group 1, 6.04 (95% CI 5.82-6.28) mg in Group 2, and 5.43 (95% CI 5.19-5.67) mg in Group 3. There were significant differences in the ED50 for motor block among the groups (P=0.008). CONCLUSIONS The ED50 doses for motor block with 3 bupivacaine concentrations were significantly different in elderly patients; the ED50 dose of 0.75% bupivacaine being significantly higher than that of 0.25% bupivacaine.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of the median effective dose for motor block of intrathecally administered different concentrations of bupivacaine in younger patients. The influence of solution concentration.

OBJECTIVE To determine the median effective dose (ED50) for motor block of intrathecally administered different concentrations of bupivacaine in younger patients. METHODS This study was conducted at the Department of Anesthesiology, The First College of Clinical Medical Science, China Three Gorges University, China, on 40 American Society of Anaesthesiologists (ASA) I-II younger patients (18-...

متن کامل

Effect of Baricity of Bupivacaine on Median Effective Doses for Motor Block

BACKGROUND The median effective dose (ED50) of a drug gives the amount or dose of drug needed to produce effective therapeutic response or desired effect in at least 50% of the population taking it. Our study focused on determining the ED50 required for effective motor block using hyperbaric and plain bupivacaine, and evaluated the influence of baricity on the ED50 required for motor block. MAT...

متن کامل

ED50 of hyperbaric bupivacaine with fentanyl for cesarean delivery under combined spinal epidural in normotensive and preeclamptic patients.

BACKGROUND AND OBJECTIVES The use of reduced intrathecal doses is advised for spinal anesthesia during cesarean delivery. However, there are inadequate data regarding the minimum effective dose of intrathecal bupivacaine for cesarean delivery. Preeclampsia is caused by an endothelial dysfunction leading to generalized vasoconstriction. Whether this can offset the pregnancy-induced decrease in i...

متن کامل

Comparison of intrathecal fentanyl and sufentanil in low-dose dilute bupivacaine spinal anaesthesia for transurethral prostatectomy.

BACKGROUND The administration of low-dose bupivacaine can limit the distribution of spinal block to reduce adverse haemodynamic effects. Intrathecal opioids can enhance analgesia in combination with subtherapeutic doses of local anaesthetics. We aimed at comparing the efficacy of intrathecal fentanyl and sufentanil with low-dose diluted bupivacaine for transurethral prostatectomy (TURP) in elde...

متن کامل

Evaluation of S1 motor block to determine a safe, reliable test dose for epidural analgesia.

BACKGROUND Accidental intrathecal injection of bupivacaine during epidural analgesia in labour remains a hazard, with the potential to cause total spinal anaesthesia and maternal collapse. Sacral block appears early after intrathecal injections compared with epidural ones, and we therefore used SI motor block to determine a safe and reliable test dose for epidural catheter misplacement. METHO...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 21  شماره 

صفحات  -

تاریخ انتشار 2015