Brain natriuretic peptide and impedance cardiography to assess volume status in peritoneal dialysis patients.

نویسندگان

  • Carlos A Granja
  • Prayus T Tailor
  • Nancy Gorban-Brennan
  • Jean Francis
  • Amenuve Bekui
  • Fredric O Finkelstein
چکیده

Assessment of volume status in patients with end-stage renal disease has long been a problem. Objective tools for estimating dry weight are necessary. The present study was designed to determine if better assessment of volume status could be achieved by measuring brain natriuretic peptide (BNP) and thoracic fluid content (TFC) by bioimpedance. We prospectively surveyed 51 medically stable peritoneal dialysis (PD) patients during their routine visits to our PD facility. There were no exclusion criteria. Clinical volume status was assessed by the attending nephrologist as hypovolemic, euvolemic, or hypervolemic. Once the clinical assessment was complete, plasma BNP concentration was measured. The TFC was determined by bioimpedance cardiography measured in the supine position. Of 51 patients, 19 (37.3%) were considered hypervolemic, 30 (58.8%) euvolemic, and 3 (5.9%) hypovolemic by clinical assessment. As defined by systolic blood pressure > or = 130 mmHg or diastolic pressure > or = 80 mmHg (or both), 57% were hypertensive. The hypovolemic group was excluded from the statistical analysis because of the small sample size. Logistic regression analysis did not show a significant correlation between clinical assessment of volume and BNP (p = 0.76) or TFC (p = 0.39). Our data demonstrate the limitations of BNP and thoracic impedance in helping with the clinical evaluation of volume status in a cohort of chronic PD patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bioelectric impedance measurement for fluid status assessment.

BACKGROUND Adequacy of body fluid volume improves short- and long-term outcomes inpatients with heart and kidney disorders. Bioelectrical impedance vector analysis (BIVA) has the potential to be used as a routine method at the bedside for assessment and management of body fluids. METHODS Impedance (Z vector) is a combination of resistance, R (function of intra- and extracellular fluid volume)...

متن کامل

Does bioimpedance analysis or measurement of natriuretic peptides aid volume assessment in peritoneal dialysis patients?

Cardiovascular mortality remains the commonest cause of death for peritoneal dialysis patients. As such, preventing persistent hypervolemia is important. On the other hand, hypovolemia may potentially risk episodes of acute kidney injury and loss of residual renal function, a major determinant of peritoneal dialysis technique survival. Bioimpedance has developed from a single-frequency research...

متن کامل

N-terminal pro-brain natriuretic peptide in prevalent peritoneal dialysis patients.

Previous reports have shown that N-terminal pro-brain natriuretic peptide (NT-Pro-BNP) is a predictive marker for mortality in both peritoneal dialysis (PD) and hemodialysis (HD) patients. The aim of the present study was to clarify whether NT-Pro-BNP reflects a specific status in PD patients. We analyzed 40 stable PD patients, allocating them to one of two groups (20 each) according to the med...

متن کامل

Relationship between Serum N-Terminal Pro-Brain Natriuretic Peptide Level and Left Ventricular Dysfunction and Extracellular Water in Continuous Ambulatory Peritoneal Dialysis Patients

This study inquired the relationship between serum N-terminal pro-brain natriuretic peptide (NT-proBNP) levels and left ventricular (LV) dysfunction and extracellular water in continuous ambulatory peritoneal dialysis (CAPD) patients. We conducted a cross-sectional study of 30 CAPD patients. Each patient was admitted to the department of internal medicine, Chosun University Hospital between Feb...

متن کامل

Is brain natriuretic peptide a reliable biomarker of hydration status in all peritoneal dialysis patients?

BACKGROUND Achievement of euvolemia is a fundamental challenge in the peritoneal dialysis (PD) population. Bioimpedance spectroscopy (BIS) is one of the best techniques for routine assessment of hydration status (HS) in PD, but in recent years, the role of brain natriuretic peptides (BNP) in the assessment of volume status has gained interest. The aim of this study was to investigate the relati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Advances in peritoneal dialysis. Conference on Peritoneal Dialysis

دوره 23  شماره 

صفحات  -

تاریخ انتشار 2007