Improved combination of spiral-in/out images for BOLD fMRI.

نویسندگان

  • Gary H Glover
  • Moriah E Thomason
چکیده

Acquisitions with the spiral-in/out technique result in two separate image timeseries obtained during the spiral-in and spiral-out trajectory. In uniform brain regions the two components have comparable signal and BOLD contrast and can be averaged, but in regions compromised by susceptibility effects where both signal and noise can differ in the two images other combination methods may be more effective. Here, several weighting schemes are compared for signal and activation contrast recovery in whole brain and prefrontal cortex using verbal working memory (seven subjects) and breathholding tasks (six subjects) scanned at 3 T. It was found that a statistically weighted combination based on activation maps derived separately from the spiral-in and spiral-out images provides activation volumes with increases of 33-59% over second-choice signal-weighted combination and 100-200% increases over spiral-out acquisition alone, and that simple averaging is inferior to signal-weighted combination.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Spiral-in/out BOLD fMRI for increased SNR and reduced susceptibility artifacts.

BOLD fMRI is hampered by dropout of signal in the orbitofrontal and parietal brain regions due to magnetic field gradients near air-tissue interfaces. This work reports the use of spiral-in trajectories that begin at the edge of k-space and end at the origin, and spiral in/out trajectories in which a spiral-in readout is followed by a conventional spiral-out trajectory. The spiral-in trajectory...

متن کامل

Comparison of spiral-in/out and spiral-out BOLD fMRI at 1.5 and 3 T.

Spiral-in/out functional magnetic resonance imaging (fMRI) methods acquire one image before the echo time (TE) and a second image after TE during each scan. Weighted combination of the two images provides a time series with reduced susceptibility dropout in frontal and medial temporal regions as well as increased signal-to-noise ratio (SNR) in regions of uniform cortex. In this study, task acti...

متن کامل

Evaluation of Sensory Pathways in Spinal Cord by Comparison of fMRI Methodologies

Introduction: Today, clinicians and neuroscientists need to have a comprehensive survey of neurological pathologies and injuries. For the First-time, SEEP contrast and Spin-Echo pulse sequences was used for functional imaging of the Lumbar spinal cord. This method used by several research groups for Spinal cord mapping, but other researchers tried to improve BOLD fMRI to Spina...

متن کامل

Repeatability of Detecting Visual Cortex Activity in Functional Magnetic Resonance Imaging

Introduction As functional magnetic resonance imaging (fMRI) is too expensive and time consuming, its frequent implementation is difficult. The aim of this study is to evaluate repeatability of detecting visual cortex activity in fMRI. Materials and Methods In this study, 15 normal volunteers (10 female, 5 male; Mean age±SD: 24.7±3.8 years) attended. Functional magnetic resonance images were ob...

متن کامل

Motion-compensated interleaved spiral acquisition for fMRI

INTRODUCTION – Typical fMRI acquisitions cannot reveal great detail about activated brain regions due to poor image resolution. At present, 64x64 voxels per slice is still the most commonly used acquisition matrix size for fMRI studies, leading to an in-plane resolution of 3.75 mm with FOV = 24 cm. Increasing spatial resolution is very time consuming, e.g. doubling in-plane resolution increases...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 51 4  شماره 

صفحات  -

تاریخ انتشار 2004