New cause for false-positive results with the cryptococcal antigen test by latex agglutination.
نویسندگان
چکیده
The highly specific and sensitive latex agglutination test for cryptococcal antigen detection in cerebrospinal fluid is routine in many hospitals. Contamination of cerebrospinal fluid by a minute amount of syneresis fluid (surface condensation) from agar gave a strongly positive reaction which was heat stable, was not eliminated by pronase treatment, and was not detected by the normal rabbit globulin controls. These observations were valid for three commercially available test kits and could represent a preventable cause of some unexplained false-positive tests despite the use of adequate controls.
منابع مشابه
False-negative cerebrospinal fluid cryptococcal latex agglutination tests for patients with culture-positive cryptococcal meningitis.
Three cases of false-negative cerebrospinal fluid latex agglutination test results for patients with culture-positive cryptococcal meningitis are reported. False-negative results occurred in settings of low cryptococcal antigen concentrations in cerebrospinal fluid and were dependent on the latex agglutination test kit used. Investigation of each case revealed that prozone phenomena or interfer...
متن کاملComparison of three commercial cryptococcal latex kits for detection of cryptococcal antigen.
Three commercial latex kits, IBL, MYCO-Immune, and IMMY, for the detection of cryptococcal antigen were compared in regard to sensitivity, specificity, and height of antigen titers. A total of 218 cerebrospinal fluid and 79 serum specimens from 239 patients were included. Twenty-two patients had culture-proven disseminated cryptococcosis. Both the IBL and MYCO-Immune kits had sensitivities of 1...
متن کاملFalse-positive reactions in the latex agglutination test for Cryptococcus neoformans antigen.
The latex agglutination test for Cryptococcus neoformans antigen is a simple and rapid procedure for the diagnosis of cryptococcal meningitis. Although the test is sensitive, care must be taken to prevent contamination of the sample, which may result in false-positive reactions. It was discovered in our laboratory that immersion of a platinum wire inoculating loop into a sample of cerebrospinal...
متن کاملEvaluation of new monoclonal antibody-based latex agglutination test for detection of cryptococcal polysaccharide antigen in serum and cerebrospinal fluid.
We evaluated the performance of CRYPTO-LEX (Trinity Laboratories, Inc., Raleigh, N. C.), a new mouse immunoglobulin M monoclonal antibody latex agglutination reagent which reacts with the capsular polysaccharide of the four serogroups of Cryptococcus neoformans. This test was compared with CALAS (Meridian Diagnostics, Cincinnati, Ohio) for the ability to detect cryptococcal antigen in serum and...
متن کاملInterference by hydroxyethyl starch used for vascular filling in latex agglutination test for cryptococcal antigen.
The glucuronoxylomannan component of the Cryptococcus neoformans capsular polysaccharide confers serotype specificity, and its detection in cerebrospinal fluid or serum by the latex agglutination test is used for diagnosis. Low-molecular-weight hydroxyethyl starches can be used as an alternative to albumin for vascular filling. This study reports the occurrence of a false-positive result with t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical microbiology
دوره 22 5 شماره
صفحات -
تاریخ انتشار 1985