Three-dimensional 1060-nm OCT: choroidal thickness maps in normal subjects and improved posterior segment visualization in cataract patients.

نویسندگان

  • Marieh Esmaeelpour
  • Boris Povazay
  • Boris Hermann
  • Bernd Hofer
  • Vedran Kajic
  • Ketan Kapoor
  • Nik J L Sheen
  • Rachel V North
  • Wolfgang Drexler
چکیده

PURPOSE To evaluate the performance and potential clinical role of three-dimensional (3D) 1060-nm OCT by generating choroidal thickness (ChT) maps in patients of different ages with different degrees of ametropia and axial lengths and to investigate the effect of cataract grade on OCT retinal imaging quality. METHODS Axial lengths (ALs) and 45° fundus photographs were acquired from 64 eyes (34 healthy subjects, 19 to 80 years, ametropia +3 to -10 D). 3D 1060-nm OCT was performed over a 36° × 36° field of view with ∼7-μm axial resolution and up to 70 frames/s (512 A-scans/frame). ChT maps between retinal pigment epithelium and the choroidal-scleral interface, were generated and statistically analyzed. A further 30 eyes (19 subjects), with cataracts assessed with the LOCS III scale, were imaged with 3D 1060-nm OCT and 800-nm OCT, and visualization of the posterior segment was compared qualitatively. RESULTS In 64 eyes, ChT maps displayed a thickness decrease with increasing AL. Subfoveal ChT was 315 ± 106 μm (mean ± SD), negatively correlated with AL (R(2) = -0.47, P < 0.001). Averaged ChT maps of eyes with AL < 23.39 mm showed an increased ChT in an area ∼1500 μm inferior, compared with subfoveal ChT. Eyes with AL > 24.5 mm showed a larger variation and a thicker ChT superiorly than inferiorly. Reduced signal strength in cataractous eyes was found in 65% of the 800-nm OCT images, but in only 10% of the 1060-nm OCT images. CONCLUSIONS The imaging performance of 3D 1060-nm OCT is unique, producing maps that show the variation in ChT over the entire field of view, in relation to axial length. This imaging system has the potential of visualizing a novel clinical diagnostic biomarker. Compared with 800-nm OCT, it provides superior visualization of the posterior pole in cataractous eyes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mapping Retinal and Choroidal Thickness in Unilateral Nongranulomatous Acute Anterior Uveitis Using Three-Dimensional 1060-nm Optical Coherence Tomography.

Purpose To analyze retinal thickness (RT) and choroidal thickness (ChT) changes in patients with unilateral nongranulomatous acute anterior uveitis (AAU) using three-dimensional (3D) 1060-nm optical coherence tomography (OCT). Methods Retinal and choroidal thickness maps were statistically analyzed for 24 patients with newly diagnosed unilateral AAU before therapy. A total of 17 patients were...

متن کامل

In vivo human choroidal vascular pattern visualization using high-speed swept-source optical coherence tomography at 1060 nm.

PURPOSE To investigate the retinal and choroidal vascular pattern, structure, and thickness using high-speed, high axial resolution, swept-source optical coherence tomography (SS-OCT) at 1060 nm, demonstrating enhanced penetration through all choroidal layers. METHODS An ophthalmic SS-OCT system was developed operating at 57,000 A-lines/s with 5.9 μm axial resolution and was used to collect 3...

متن کامل

Mapping choroidal and retinal thickness variation in type 2 diabetes using three-dimensional 1060-nm optical coherence tomography.

PURPOSE To map choroidal (ChT) and retinal thickness (RT) in healthy subjects and patients with diabetes with and without maculopathy using three dimensional 1060-nm optical coherence tomography (3D-1060nm-OCT). METHODS Sixty-three eyes from 42 diabetic subjects (41-82 years of age; 11 females) grouped according to a custom scheme using Early Treatment Diabetic Retinopathy Study definitions f...

متن کامل

Evaluation of Normal Choroidal Thickness in Rasht Using SD-OCT EDI Imaging

Purpose: To measure choroidal thickness in normal subjects, using optical coherent tomography (OCT) in Rasht. Methods: Normal subjects older than 20 years, living in Rasht, were selected through systematic random sampling by using the city telephone directory. The subjects underwent comprehensive eye examinations for inclusion in the study. Then, choroidal thickness was measured in both eyes by...

متن کامل

Macular choroidal thickness and volume in normal subjects measured by swept-source optical coherence tomography.

PURPOSE To study the choroidal thickness in healthy subjects by swept-source optical coherence tomography (SS-OCT) at longer wavelength. METHODS The macular area of 31 eyes (31 healthy volunteers) was studied with an SS-OCT prototype system, which uses a tunable laser as a light source operated at 100,000 Hz A scan repetition rate in the 1-μm wavelength region. Three-dimensional volumetric me...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 51 10  شماره 

صفحات  -

تاریخ انتشار 2010