Comparison of image quality with 62Cu and 64Cu-labeled radiotracers in positron emission tomography whole-body phantom imaging.

نویسندگان

  • Masato Kobayashi
  • Tetsuya Mori
  • Tetsuya Tsujikawa
  • Kazuhiro Ogai
  • Jyunko Sugama
  • Yasushi Kiyono
  • Keiichi Kawai
  • Hidehiko Okazawa
چکیده

OBJECTIVE PET imaging is possible with copper (Cu) isotopes, (60)Cu, (61)Cu, (62)Cu and (64)Cu. Although (62)Cu- and (64)Cu-labeled radiotracers are often used for preclinical and clinical PET studies, we do not know which radiotracers have better image quality for tumor imaging. In this study, we compare image quality between (62)Cu and (64)Cu imaging with a different acquisition mode and reconstruction algorithm using a whole-body phantom for tumor imaging. METHODS In a National Electrical Manufacturers Association (NEMA) 2001 whole-body phantom, the concentration of (62)Cu-ATSM and (64)Cu-ATSM was, respectively, approximately 2.7 and 1.8MBq/mL in all the spheres and approximately 0.9 and 0.6MBq/mL in the background. After adjustment for true coincidence events between (62)Cu and (64)Cu, two-dimensional (2D) and three-dimensional (3D) PET scan data were acquired for 10min. The data were reconstructed using filtered back projection (FBP) and the ordered subset expectation maximization (OSEM) algorithm. Image quality of (62)Cu and (64)Cu was compared using recovery coefficient (RC), sphere-to-background ratio (SBR) and coefficient of variation (%COV). RESULTS There were little significant differences between (62)Cu and (64)Cu imaging, visually. Recovery coefficients of (64)Cu images were higher than those of (62)Cu images. The RC of (64)Cu images with 3D acquisition mode and OSEM was the highest in all experiments. No SBR values were significantly different from the true value of 3.0 in 37mm sphere diameters, but 3D acquisition and OSEM yielded slight overestimations compared with 2D acquisition and FBP, the gold standard for quantification in PET studies. Percentage COV values of (64)Cu with OSEM were significantly lower than those of (62)Cu. CONCLUSIONS Copper-64 radiotracers provide higher image quality than (62)Cu-radiotracers in whole-body tumor imaging only when the 3D acquisition mode and OSEM algorithm are applied. However, the quantitative values for smaller tumors may be slightly overestimated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Imaging Cellular Proliferation in Prostate Cancer with Positron Emission Tomography

Prostate cancer remains a major public health problem worldwide. Imaging plays an important role in the assessment of disease at all its clinical phases, including staging, restaging after definitive therapy, evaluation of therapy response, and prognostication. Positron emission tomography with a number of biologically targeted radiotracers has been demonstrated to have potential diagnostic and...

متن کامل

Calculation of Positron Distribution in the Presence of a Uniform Magnetic Field for the Improvement of Positron Emission Tomography (PET) Imaging Using GEANT4 Toolkit

Introduction Range and diffusion of positron-emitting radiopharmaceuticals are important parameters for image resolution in positron emission tomography (PET). In this study, GEANT4 toolkit was applied to study positron diffusion in soft tissues with and without a magnetic field for six commonly used isotopes in PET imaging including 11C, 13N, 15O, 18F, 68Ga, and 82Rb. Materials and Methods GEA...

متن کامل

Characteristics of Smoothing Filters to Achieve the Guideline Recommended Positron Emission Tomography Image without Harmonization

Objective(s): The aim of this study is to examine the effect of different smoothing filters on the image quality and SUVmax to achieve the guideline recommended positron emission tomography (PET) image without harmonization. Methods: We used a Biograph mCT PET scanner. A National Electrical Manufacturers Association (NEMA) the International Electrotechnical Commission (IEC) body phantom was fil...

متن کامل

Importance of defect detectability in Positron Emission Tomography imaging of abdominal lesions

Objective(s): This study was designed to assess defect detectability in positron emission tomography (PET) imaging of abdominal lesions. Methods: A National Electrical Manufactures Association International Electrotechnical Commission phantom was used. The simulated abdominal lesion was scanned for 10 min using dynamic list-mode acquisition method. Images, acquired with scan duration of 1-10 mi...

متن کامل

PET Radiopharmaceuticals

PET (positron emission tomography) is a powerful imaging technique that can provide quantitative information on the distribution of positron emitter labeled radiopharmaceuticals (PET radiopharmaceuticals) in the body. Positrons (ß+) are positively charged beta particles. They are emitted when the atom is proton rich. A positron has only a transient existence. After losing all of its kinetic ene...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Hellenic journal of nuclear medicine

دوره 18 2  شماره 

صفحات  -

تاریخ انتشار 2015