A small area in-situ MEMS test structure to measure fracture strength by electrostatic probing

نویسندگان

  • Maarten P. de Boer
  • Brian D. Jensen
چکیده

We have designed, fabricated, tested and modeled a first generation small area test structure for MEMS fracture studies by electrostatic rather than mechanical probing. Because of its small area, this device has potential applications as a lot monitor of strength or fatigue of the MEMS structural material. By matching deflection versus applied voltage data to a 3-D model of the test structure, we develop high confidence that the local stresses achieved in the gage section are greater than 1 GPa. Brittle failure of the polycrystalline silicon was observed.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In situ strength assessment of concrete using recycled aggregates by means of small diameter cores.

By increasing the demolition of old concrete structures and the interest of civil industries to consume cheaper materials, using Recycled Concrete Aggregate (RCA) can cause environmental protection and decrease the construction costs. On the other hand, the high potential of Recycled Aggregate Concrete (RAC) in concrete industry was established by extensive experimental researches were performe...

متن کامل

A New Design of Dual Band Phase Shifter using MEMS Technology

Abstract - This paper presents a new design of microwave microelectromechanical systems (MEMS) phase shifter for dual band wireless local area network (WLAN) applications. A bit is designed which product a constant phase shift of 11.25° by switching between two line that consist of 12 and 6 unitcells in each frequency band. A unitcell is constructed by gold membrane suspended over the coplanar ...

متن کامل

The Validity Assessment of Laboratory Shear Modulus Using In-Situ Seismic Piezocone Test Results

Seismic piezocone device (SCPTu) together with Resonant Column and Cyclic Triaxial test apparatus are employed to measure small strain shear modulus (G0) of carbonate sandy and clayey soils of southern coasts of Iran. A large area of southern regions of Iran is formed from clay, silt and sand. In this study, maximum shear modulus that is derived from both field (by seismic piezocone) and labora...

متن کامل

Design and Simulation of a Fluidic Micro-Bio-Sensor Based on Resonator Array

In this paper, a fluidic biosensor with possibility to fabricate by Micro-Electro-Mechanical Systems (MEMS) technology is proposed for biomedical mass detection and lab-on-chip applications. This is designed by electromechanical coupling of harmonic micromechanical resonators with harmonic springers as a mechanical resonator array. It can disperse mechanical wave along the array by electrostati...

متن کامل

State Estimation of MEMs Capacitor Using Taylor Expansion

This paper deals with state estimation of micro tunable capacitor subjected to nonlinear electrostatic force. For this end a nonlinear observer has been designed for state estimation of the structure.  Necessary and sufficient conditions for construction of the observer are presented. Stability of the observer is checked using Lyapunov theorem. Observer design is based on converting of differen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1999